Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
Previous page Next page
The settings panel of the RS-RTP server object is shown in figures.
The General tab
The Device list tab
The Connection to external server tab
The table describes the parameters of the settings corresponding to the elements of the settings panel of the RS-RTP object.
# | Name | Field type | Description | Format | Default value | Value range |
1 | ID | Automatically | Shows id of RS-RTP Server object in the system | Natural number series | - | Depends on the number of RS-RTP Server objects in the system |
2 | Name | Enter the value in the field | Sets the name of RS-RTP Server object | Latin, Cyrillic and service characters | RS-RTP server | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Checkbox | Sets the state of RS-RTP Server object (disabled or enabled) | Boolean type | No | Yes – RS-RTP Server object is disabled and is not in use. No – RS-RTP Server object is enabled and is in use. |
4 | Computer | Select in the list | Sets the parent Computer object in the digital system with distributed architecture to which the RS-RTP Server object is assigned. | Names of the Computer objects registered in the system
| The name of the parent Computer object | Depends on the number of Computer objects in the digital surveillance system with distributed architecture. |
The General tab | ||||||
5 | IP: | Select in the list | Sets IP address of network interface using which the third-party software will control registered in Intellect devices via the GB2818 protocol | IP address | Depends on the parameters of network connection | Depends on the parameters and number of network connections |
6 | Port: | Enter the value in the field | Number of a port through which the third party software will be connected via the GB2818 protocol | Natural number series | 5060 | 0-65535 |
7 | Transport: | Select value in the list | Data transfer protocol | Supported transport protocols | UDP | UDP, TCP |
8 | Server ID | Automatically | ID of Intellect Server that is in use by the third-party software to connect to RS-RTP Server via the GB2818 protocol | - | - | - |
9 | From: | Enter the value in the field | Lower value of the RTP port range | Natural number series | - | 0-65535 |
10 | To: | Enter the value in the field | Upper limit of the RTP port range | Natural number series | - | 0-65535 |
The Device list tab | ||||||
11 | Type | Select value in the list | Type of object to be controlled via the GB2818 protocol | Names of types of objects in Intellect object tree | - | Depends on the number of objects created in Intellect object tree
|
12 | Name | Select value in the list | Name of object to be controlled via the GB2818 protocol | Names of objects in Intellect object tree | - | Depends on the number of objects created in Intellect object tree |
13 | Device ID | Automatically | ID of the device that will be in use in the third-party software to control objects via the GB2818 protocol | - | - | - |
The Connection to edge server tab | ||||||
14 | Edge server connection | Checkbox | Checks if Intellect connects to edge supserver using the PS-RTP object via the GB2818 protocol | Boolean type | No | Yes – edge server connection is performed. No – edge server connection is not performed. |
15 | IP: | Enter the value in the field | IP address of supserver | IP address | - | 000.000.000.000 – 255.255.255.255 |
16 | Port: | Enter the value in the field | Port used to connect to edge server | Natural number series | 5060 | 0-65535 |
17 | Transport: | Select value in the list | Transport protocol used to connect to edge server | Supported transport protocols | - | TCP, UPD |
18 | Login: | Enter the value in the field | Username used to connect to edge server | Latin, Cyrillic and service characters | - | A line containing a sequence of any symbols |
19 | Password: | Enter the value in the field | Password used to connect to edge server | Latin, Cyrillic and service characters | - | A line containing a sequence of any symbols |
20 | Server ID: | Enter the value in the field | ID of supserver via the GB28181 protocol | Natural number series | - | 00000000000000000000 - 99999999999999999999 |