Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

The settings panel of the RS-RTP server object is shown in figures.

 

The General tab

 

The Device list tab

 

The Connection to external server tab

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the RS-RTP object.

#

Name

Field type

Description

Format

Default value

Value range

1

ID

Automatically

Shows id of RS-RTP Server object in the system

Natural number series

-

Depends on the number of RS-RTP Server objects in the system

2

Name

Enter the value in the field

Sets the name of RS-RTP Server object

Latin, Cyrillic and service characters

RS-RTP server

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Checkbox

Sets the state of RS-RTP Server object (disabled or enabled)

Boolean type

No

YesRS-RTP Server object is disabled and is not in use.

NoRS-RTP Server object is enabled and is in use.

4

Computer

Select in the list

Sets the parent Computer object in the digital system with distributed architecture to which the RS-RTP Server object is assigned.

Names of the Computer objects registered in the system

 

The name of the parent Computer object

Depends on the number of Computer objects in the digital surveillance system with distributed architecture.

The General tab

5

IP:

Select in the list

Sets IP address of network interface using which the third-party software will control registered in Intellect devices via the GB2818 protocol

IP address

Depends on the parameters of network connection

Depends on the parameters and number of network connections

6

Port:

Enter the value in the field

Number of a port through which the third party software will be connected via the GB2818 protocol

Natural number series

5060

0-65535

7

Transport:

Select value in the list

Data transfer protocol

Supported transport protocols

UDP

UDP, TCP

8

Server ID

Automatically

ID of Intellect Server that is in use by the third-party software to connect to RS-RTP Server via the GB2818 protocol 

-

-

-

9

From:

Enter the value in the field

Lower value of the RTP port range

Natural number series

-

0-65535

10

To:

Enter the value in the field

Upper limit of the RTP port range

Natural number series

-

0-65535

The Device list tab

11

Type

Select value in the list

Type of object to be controlled via the GB2818 protocol

Names of types of objects in Intellect object tree

-

Depends on the number of  objects created in Intellect object tree

 

12

Name

Select value in the list

Name of object to be controlled via the GB2818 protocol

Names of objects in Intellect object tree

-

Depends on the number of  objects created in Intellect object tree

13

Device ID

Automatically

ID of the device that will be in use in the third-party software to control objects via the GB2818 protocol

-

-

-

The Connection to edge server tab

14

Edge server connection

Checkbox

Checks if Intellect connects to edge supserver using the PS-RTP object via the GB2818 protocol

Boolean type

No

Yes – edge server connection is performed.

No – edge server connection is not performed.

15

IP:

Enter the value in the field

IP address of supserver

IP address

-

000.000.000.000 – 255.255.255.255

16

Port:

Enter the value in the field

Port used to connect to edge server

Natural number series

5060

0-65535

17

Transport:

Select value in the list

Transport protocol used to connect to edge server

Supported transport protocols

-

TCP, UPD

18

Login:

Enter the value in the field

Username used to connect to edge server

Latin, Cyrillic and service characters

-

A line containing a sequence of any symbols

19

Password:

Enter the value in the field

Password used to connect to edge server

Latin, Cyrillic and service characters

-

A line containing a sequence of any symbols

20

Server ID:

Enter the value in the field

ID of supserver via the GB28181 protocol

Natural number series

-

00000000000000000000 - 99999999999999999999

  • No labels