The settings panel of the Operator protocol object is shown in the figures. The tables below them describe the parameters of the settings corresponding to the elements of the settings panel of the Operator protocol.
The table describes the parameters of the settings corresponding to the elements of the settings panel of the Operator protocol.
No. | Parameter | Method for specifying the parameter | Parameter description | Symbols | Default value | Range of values |
The Filters tab | ||||||
1 | The Identification number field * | Automatically | Shows the identification number of the Operator protocol object in the system | Sequence of numbers | - | Depends on the number of Operator protocol objects in the system |
2 | The Name field * | Type-in the value in the field | Assigns the name to the Operator protocol object. | Latin, Cyrillic and service characters | Operator protocol | A line containing a sequence of any symbols (letters, digits, service, characters apart from > and < symbols), non case-sensitive Number of symbols – from 1 to 60. |
3 | The Disable checkbox | Checkbox is set | Shows the status (enabled or disabled) of the Operator protocol object in the system | Boolean type | No | Yes – the Operator protocol object is disabled and is not in use. No – the Operator protocol object is enabled and is in use. |
4 | The Display dropdown list | Is selected in the list | Assigns the parent Display object , to which the given Operator protocol object refers. | Name of the Display objects registered in the system. | Name of the parent Display object | Depends on the number of the Display objects in the system. |
5 | The X filed | Type-in the value in the field | Sets the coordinate in the X horizontal axis for the upper left corner of the Operator protocol interface object on the screen | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed. |
The Y field | Type-in the value in the field | Sets the coordinate in the Y vertical axis for the upper left corner of the Operator protocol interface object on the screen | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed. | |
6 | The W filed | Type-in the value in the field | Sets the window width of the Operator protocol interface object | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed. |
The H field | Type-in the value in the field | Sets the window height of the Operator protocol interface object | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed. | |
7 | The Allow moving checkbox | Checkbox is set | Allows hand shifting of the Operator protocol interface box | Boolean type | No | Yes – hand shifting is allowed. No – hand shifting is prohibited. |
8 | The X button | Click the button | Opens a template box to set size and position of the Operator protocol interface window | - | - | - |
9 | The Monitor dropdown list | Select in the list | Sets the system ID of the monitor for which the coordinates are set | IDs of the monitors in the OS | 1 | From 1 to 16 |
10 | The Add event button | Click the button | Opens the window for bulk adding events of an object of the selected type | - | - | - |
11 | The Type drop-down list | Select in the list | Sets the type of objects which are to be displayed in the Operator protocol interface box | Available object types | - | Depends on the registered objects in the system. Only objects for which the INFORMATION or ALARM value is selected in the Messages processing column on the Events tab in the ddi.exe utility are available for selection (see The Events tab section). |
12 | The Number drop-down list | Select in the list | Sets the number of object on which the events are to be displayed in the Operator protocol interface box | Sequence of numbers | - | Depends on the number of registered objects of the specified type |
13 | The Name drop-down list | Automatically | Sets the name of object on which the events are to be displayed in the Operator protocol interface box | Names of objects registered in the system | - | Depends on the objects registered in the system |
14 | The Event type drop-down list | Select in the list | Sets events displayed in the Operator protocol interface box | Available events for the selected object | - | Depends on the object type |
15 | The Request password drop-down list | Select in the list | Defines the necessity of password to process the event | Boolean type | - | Yes – confirmation of the password is required to process the event; No – confirmation of the password is not required to process the event. |
16 | The Region drop-down list | Select in the list | Specifies the Region object corresponding to the monitored object | List of created Region objects | - | Depends on the number of created Region objects |
17 | The Parameter field | Type-in the value in the field | Sets the parameter of the monitored object. | Depends on the event type | - | Depends on the event type. |
18 | The Value field | Type-in the value in the field | Sets the parameter value of the monitored object. | Depends on the event type | - | Depends on the event type |
19 | The Help file field | Type-in the value in the field | Sets the full path to the text file in pdf, doc, docx, txt or other format which contains the helping guide about the event processing. | File address in the file system. | - | Depends on the file system limitations. |
20 | The Priority drop-down list | Select in the list | Sets the event priority for sorting by importance | Non-negative integer | - | 1 – 10 The higher the value, the higher the priority |
The Parameters table | ||||||
21 | The Parameter field | Type-in the value in the field | Sets the name of parameter, the value of which is to be displayed in the Operator protocol interface object | Latin, Cyrillic and service characters | - | Depends on parameters sent with event |
22 | The Description field | Type-in the value in the field | Type-in the short description of the specified parameter | Latin, Cyrillic and service characters | - | 0-255 characters |
The Checklist table | ||||||
23 | The Description field | Type-in the value in the field | Sets the description of the action that the operator must perform before assigning the status to an event. | Latin, Cyrillic and service characters | - | 0-255 characters |
Outside the groups | ||||||
24 | The Chief interfaces dropdown list | Checkbox is set | Sets the Operator protocol object to which the events are to be sent after the time specified in the Wait for operator response for field | List of available Operator protocol objects | - | Depends on the number of created Operator protocol objects in the system. |
25 | The Map dropdown list | Select in the list | Sets the Map interface object to display the monitored object | List of available Map objects in the system | - | Depends on the number of the Map objects created in the system |
26 | The Video dropdown list | Select in the list | Sets the method of the archive and live video displaying from the operator’s protocol. | List of available displaying methods | ActiveX | ActiveX - archive and live video will open in a separate window. Monitor - archive and live video will open on the selected Video Surveillance Monitor. |
27 | The Wait for operator response for field | Type-in the value in the field | Sets the time after which the event type becomes Not-processed event or the event is escalated | Min | 2.5 | 0-10000 Fractional values can be specified; integer and fractional parts are point-separated. For instance, to set 2 minutes 30 seconds time period specify 2.5. |
28 | The Store events field | Type-in the value in the field | Specifies the maximum events that can be displayed simultaneously in the list of current events | Sequence of numbers | 100 | Integer that is more than 0 |
29 | The Delay decision making for field | Type-in the value in the field | Sets the time for which the operator can delay the event processing | Min | - | 0-600 The value is not specified or 0 – the operator can not delay the event processing. Greater than 0 – the parameter sets the time for which the operator can delay the event processing. It is possible to specify fractional values, the separator of the integer and fractional part is a point. For example, to set a period of 2 minutes and 30 seconds 2.5 should be specified. |
30 | The Sort by priority checkbox | Checkbox is set | Enables sorting by priority. The descending sorting is performed in this order: Escalated, Alarm, Information and Standard (three latest event parameters can be set in the DDI file - see The Events tab). | Boolean type | Yes | Yes – sorting by priority is enabled. No – sorting by time events are received is enabled. |
31 | The New events at the end checkbox | Checkbox is set | Places new events at the end of the current events list | Boolean type | No | Yes – a new event is placed to the end of the list No – a new event is added to the beginning of the list |
32 | The Close elsewhere checkbox | Checkbox is set | Decides whether to delete the event from other Operator protocols when it is processed in one of the Operator protocol | Boolean type | No | Yes – when the event is processed in one of the Operator protocol, it is deleted from other Operator protocols No – when the event is processed in one of the Operator protocol, it stays unprocessed in other Operator protocols |
33 | The Password for closing checkbox | Checkbox is set | Defines the necessity to enter the password to process the event | Boolean type | No | Yes – event processing is to be confirmed with a password; No – password is not required for event processing. |
34 | The Autoswitch checkbox | Checkbox is set | Enables auto switch to the Current events tab in the Operator protocol window when a new event occurs. | Boolean type | No | Yes – auto switch is enabled No – auto switch is disabled |
35 | The Autoactivation of last event checkbox | Checkbox is set | Enables the automatic activation of the last received event tile. | Boolean type | No | Yes – the last received event tile is automatically activated; No – when the new event is received, the tile selected by the Operator remains active. |
36 | The Hide buttons for groups checkbox | Checkbox is set | Enables hiding the event handling buttons when selecting a group of events | Boolean type | No | Yes – event handling buttons are displayed when a group of events is selected No – event handling buttons are hidden when a group of events is selected |
37 | The Clear comment checkbox | Checkbox is set | Enables the comment field clearing after the event is processed by the Operator | Boolean type | No | Yes – the comment field is automatically cleared after the event is processed by the Operator; No – the comment text remains in the comment field after the event is processed by the Operator. |
38 | The Fit window size checkbox | Checkbox is set | Enables the automatic enlarging the alarm tile to fit the entire Operator protocol window size | Boolean type | No | Yes - the alarm tile size is set equal to the size of the Operator Protocol window area which is not occupied by the event control panel; No - the tile size is set according to the content size. |
39 | The Hide "Apply to all" checkbox | Checkbox is set | Disables the Apply to all button | Boolean type | No | Yes - the Apply to all button is hidden in the Operator Protocol window, and the Operator is not able to process all alarms at once; No - the Apply to all button is available in the Operator Protocol window. |
40 | The Over all windows checkbox | Checkbox is set | Enables the Operator protocol to be displayed always on top. | Boolean type | No | Yes – the Operator protocol window is always displayed above all other windows. No – the Operator protocol window is displayed normally. |
41 | The Comment required checkbox | Checkbox is set | Prevents event processing without comment | Boolean type | No | Yes – the buttons for classifying events (Alarm situation, Suspicious situation, False alarm) do not appear until the Comment field is filled. No – the operator can classify (process) the event without entering a comment. |
42 | The Single selection checkbox | Checkbox is set | Prohibits the Operator from selecting multiple events using the Shift and Ctrl keys | Boolean type | No | Yes – the ability to select multiple events using the Shift and Ctrl keys is disabled. No – the ability to select multiple events using the Shift and Ctrl keys is enabled. |
No. | Parameter | Method for specifying the parameter | Parameter description | Symbols | Default value | Range of values |
1 | The Server field | Type-in the value in the field | Sets the name of DB server in which the required database is stored | Latin, Cyrillic and service characters | Name of Server used by system | - |
2 | The Folder field | Type-in the value in the field | Sets the name of the database in which the events are to be stored | Latin, Cyrillic and service characters | Name of main database used by system | - |
3 | The User field | Type-in the value in the field | Sets the user name for authorization in the database server | Latin, Cyrillic and service characters | - | - |
4 | The Password field | Type-in the value in the field | Sets the password for authorization in the database server | Latin, Cyrillic and service characters | - | - |
5 | The Connection dialog button | Click the button | Opens the dialog box of database server connection | - | - | - |
No. | Parameter | Method for specifying the parameter | Parameter description | Symbols | Default value | Range of values |
1 | The Server field | Type-in the value in the field | Sets the name of DB server in which the required Event Protocol database is stored (if extracted to a separate DB) | Latin, Cyrillic and service characters | Name of Server used by Event Protocol database (if extracted to a separate DB) | - |
2 | The Folder field | Type-in the value in the field | Sets the name of the Event Protocol database (if extracted to a separate DB) in which the events are to be stored | Latin, Cyrillic and service characters | Name of Event Protocol database (if extracted to a separate DB) used by system | - |
3 | The User field | Type-in the value in the field | Sets the user name for authorization in the Event Protocol database (if extracted to a separate DB) server | Latin, Cyrillic and service characters | - | - |
4 | The Password field | Type-in the value in the field | Sets the password for authorization in the Event Protocol database (if extracted to a separate DB) server | Latin, Cyrillic and service characters | - | - |
5 | The Connection dialog button | Click the button | Opens the dialog box of Event Protocol database (if extracted to a separate DB) server connection | - | - | - |
No. | Parameter | Method for specifying the parameter | Parameter description | Symbols | Default value | Range of values |
1 | The Frame drop-down list | Select in the list | Sets the frame color of the active event tile | Color palette | Black | RGB color |
2 | The Name text field * | Type-in the value in the field | Sets the custom names for the alarm processing buttons | Latin, Cyrillic and service characters | No | 0-255 characters |
3 | The Keyboard shortcut text field * | Press the key combination | Sets the hot keys for the alarm events processing | Keyboard combinations | No | It is allowed to combine the Ctrl, Alt and Shift keys with any other keys on the keyboard. For example, the Ctrl+Shift+Alt+A or the Ctrl+A shortcuts are allowed, but the D+A or D+Ins shortcuts are not allowed, etc. |
4 | The View drop-down list | Select in the list | Sets a way of displaying events on the Current events tab | Available display options | Operator | Operator: the operator can choose a full or simple view. Full: the events are displayed as cells with screenshots. Simple: the events are displayed as strings without screenshots. |
5 | The Group by drop-down list | Select in the list | Sets a way of grouping events on the Current events tab | Available grouping options | Operator | Operator: the operator can choose the grouping options. Default: the event grouping is disabled. Object: the events are grouped by object. Event: the events are grouped by event type. Region: the events are grouped by region. |
* The field names marked with the asterisk * are not displayed on the settings panel.