When you are working with Lists of Facial Templates, you can configure the macros to trigger on the following events:

  1. If the target face shows up in the selected list.
  2. If the target face does not show up in the selected List of Facial Templates.
  3. Recognition of a specific face from the selected List of Facial Templates.
  4. If the target face does not show up in all available lists.
  5. Recognition of any face from any List of Facial Templates.

Target face shows up in the selected List of Facial Templates

In this case, configure the macro as follows:

  1. Go to the Start conditions in the Face recognition list and select the required List of Facial Templates (1).
  2. Leave the field 2 empty.
  3. The status of the Presence toggle (3).

The target face does not show up in the selected List of Facial Templates

In this case, configure the macro as follows:

  1. Go to the Start conditions in the Face recognition list and select the required List of Facial Templates (1).
  2. Leave the field 2 empty.
  3. The status of the Absence toggle (3).

Recognition of a specific face from the selected List of Facial Templates

In this case, configure the macro as follows:

  1. Go to the Start conditions field in the Face recognition list and select the required list (1).
  2. Select a specific face in field 2.

    Note

    To select another person, clear the 2 field and re-open the list.

The target  number does not show up in all available Lists of Facial Templates

In this case, configure the macro as follows:

  1. Go to the Start conditions field in the Face recognition list and select Not listed (1).

  2. Leave the field 2 empty.
  3. The status of the Presence toggle (3).

Recognition of any number from any List of Facial Templates

In this case, configure the macro as follows:

  1. Go to the Start conditions field in the Face recognition list and select Not listed (1).

  2. Leave the field 2 empty.
  3. The status of the Absence toggle (3).