Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

Attention!

The PS-RTP Server object was excluded from Intellect since the version 4.11.3.

The settings panel of the PS-RTP Server object is shown in figures.

 

The Main tab.

 

The List of devices tab.

 

The Connection to external server tab.

The table describes the settings parameters of the PS-RTP Server system object.

#

Parameter name

Method of setting the parameter value

Parameter description

Format

Default value

Value range

1

ID

Automatically

Displays the ID of the PS-RTP Server object in the system

Natural number series

-

Depends on the number of the PS-RTP Server objects in the system

2

Name

Enter the value in the field

Sets the name of the PS-RTP Server object

Latin, Cyrillic and service characters

PS-RTP Server

A line containing a sequence of any symbols (letters, digits, service characters except for the > and < symbols), not case-sensitive

Number of symbols – from 1 to 60

3

Disable

Set the checkbox

Sets the state of the PS-RTP Server object (disabled or enabled)

Boolean type

No

Set – PS-RTP Server object is disabled and not in use

Clear – PS-RTP Server object is enabled and in use

4

Computer

Select the value from the list

Sets the Computer parent object of the digital system with the distributed architecture to which the PS-RTP Server object is assigne

Names of the Computer objects registered in the system


The name of the Computer parent object

Depends on the number of Computer objects in the digital surveillance system with the distributed architecture

The Main tab

5

IP

Select the value from the list

Sets the IP address of the network interface using which the third-party software will control the registered in Intellect devices via the GB2818 protocol

IP address

Depends on the parameters of the network connection

Depends on the parameters and the number of the network connections

6

Port

Enter the value in the field

Number of the port through which the third party software will be connected via the GB2818 protocol

Natural number series

5060

0-65535

7

Transport

Select the value from the list

Transport protocol for the data transfer

Supported transport protocols

UDP

UDP, TCP

8

from

Enter the value in the field

Lower limit of the RTP port range

Natural number series

-

0-65535

9

to

Enter the value in the field

Upper limit of the RTP port range

Natural number series

-

0-65535

10Server IDAutomaticallyThe ID of Intellect Server that is used by the third-party software to connect to the RS-RTP Server via the GB2818 protocol ---

The List of devices tab

11

Type

Select the value from the list

The type of object to be controlled via the GB2818 protocol

Names of the types of objects in Intellect objects tree

-

Depends on the number of the objects created in Intellect objects tree


12

Name

Select the value from the list

The name of the object to be controlled via the GB2818 protocol

Names of the objects in Intellect objects tree

-

Depends on the number of the objects created in Intellect objects tree

13

Device ID

Automatically

The ID of the device that will be used in the third-party software to control objects via the GB2818 protocol

-

-

-

The Connection to external server tab

14

External server connection

Set the checkbox

Defines if Intellect connects to the external supserver using the PS-RTP Server object via the GB2818 protocol

Boolean type

No

Set – the external server connection is performed

Clear – the external server connection is not performed

15

IP

Enter the value in the field

IP address of the supserver

IP address

-

000.000.000.000 – 255.255.255.255

16

Port

Enter the value in the field

Port used to connect to the external server

Natural number series

5060

0-65535

17

Transport

Select the value from the list

Transport protocol used to connect to the external server

Supported transport protocols

-

TCP, UPD

18

Login

Enter the value in the field

Username used to connect to the external server

Latin, Cyrillic and service characters

-

A line containing a sequence of any symbols

19

Password

Enter the value in the field

Password used to connect to the external server

Latin, Cyrillic and service characters

-

A line containing a sequence of any symbols

20

Server ID

Enter the value in the field

The ID of the supserver via the GB28181 protocol

Natural number series

-

00000000000000000000 - 99999999999999999999

  • No labels