Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
Previous page Next page
Attention!
The PS-RTP Server object was excluded from Intellect since the version 4.11.3.
The settings panel of the PS-RTP Server object is shown in figures.
The Main tab.
The List of devices tab.
The Connection to external server tab.
The table describes the settings parameters of the PS-RTP Server system object.
# | Parameter name | Method of setting the parameter value | Parameter description | Format | Default value | Value range |
1 | ID | Automatically | Displays the ID of the PS-RTP Server object in the system | Natural number series | - | Depends on the number of the PS-RTP Server objects in the system |
2 | Name | Enter the value in the field | Sets the name of the PS-RTP Server object | Latin, Cyrillic and service characters | PS-RTP Server | A line containing a sequence of any symbols (letters, digits, service characters except for the > and < symbols), not case-sensitive Number of symbols – from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state of the PS-RTP Server object (disabled or enabled) | Boolean type | No | Set – PS-RTP Server object is disabled and not in use Clear – PS-RTP Server object is enabled and in use |
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture to which the PS-RTP Server object is assigne | Names of the Computer objects registered in the system | The name of the Computer parent object | Depends on the number of Computer objects in the digital surveillance system with the distributed architecture |
The Main tab | ||||||
5 | IP | Select the value from the list | Sets the IP address of the network interface using which the third-party software will control the registered in Intellect devices via the GB2818 protocol | IP address | Depends on the parameters of the network connection | Depends on the parameters and the number of the network connections |
6 | Port | Enter the value in the field | Number of the port through which the third party software will be connected via the GB2818 protocol | Natural number series | 5060 | 0-65535 |
7 | Transport | Select the value from the list | Transport protocol for the data transfer | Supported transport protocols | UDP | UDP, TCP |
8 | from | Enter the value in the field | Lower limit of the RTP port range | Natural number series | - | 0-65535 |
9 | to | Enter the value in the field | Upper limit of the RTP port range | Natural number series | - | 0-65535 |
10 | Server ID | Automatically | The ID of Intellect Server that is used by the third-party software to connect to the RS-RTP Server via the GB2818 protocol | - | - | - |
The List of devices tab | ||||||
11 | Type | Select the value from the list | The type of object to be controlled via the GB2818 protocol | Names of the types of objects in Intellect objects tree | - | Depends on the number of the objects created in Intellect objects tree |
12 | Name | Select the value from the list | The name of the object to be controlled via the GB2818 protocol | Names of the objects in Intellect objects tree | - | Depends on the number of the objects created in Intellect objects tree |
13 | Device ID | Automatically | The ID of the device that will be used in the third-party software to control objects via the GB2818 protocol | - | - | - |
The Connection to external server tab | ||||||
14 | External server connection | Set the checkbox | Defines if Intellect connects to the external supserver using the PS-RTP Server object via the GB2818 protocol | Boolean type | No | Set – the external server connection is performed Clear – the external server connection is not performed |
15 | IP | Enter the value in the field | IP address of the supserver | IP address | - | 000.000.000.000 – 255.255.255.255 |
16 | Port | Enter the value in the field | Port used to connect to the external server | Natural number series | 5060 | 0-65535 |
17 | Transport | Select the value from the list | Transport protocol used to connect to the external server | Supported transport protocols | - | TCP, UPD |
18 | Login | Enter the value in the field | Username used to connect to the external server | Latin, Cyrillic and service characters | - | A line containing a sequence of any symbols |
19 | Password | Enter the value in the field | Password used to connect to the external server | Latin, Cyrillic and service characters | - | A line containing a sequence of any symbols |
20 | Server ID | Enter the value in the field | The ID of the supserver via the GB28181 protocol | Natural number series | - | 00000000000000000000 - 99999999999999999999 |