Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

The settings panel of the SIP-terminal object is shown in the pictures below.

Table describes the parameters of the SIP-terminal settings panel.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1

The Identification number field

Automatically

Shows the identification number of the

SIP-terminal object in the system.

Sequence of numbers

-

Depends on the number of the SIP-terminal objects in the system.

2

The Name field

Enter the value in the field

Assigns a name to the SIP-terminal object in the system.

Latin, Cyrillic letters and service characters

SIP-terminal

A line representing a sequence of any symbols

(letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

The Disable checkbox

Is set with a checkbox

Shows the status (enabled or disabled) of the SIP-terminal object in the system.

Boolean type

-

Yes – the SIP-terminal object is disabled and is not in use.

No – the SIP-terminal object is enabled and is in use.

4

The Computer dropdown list

Is selected in the list

Assigns the parent Computer object for the SIP-terminal object.

Name of the Computer objects

registered in the system.

Name of the parent

Computer object

Depends on the number of the Computer objects in the system.

5The Terminal type switchSet switch to the required positionSets the SIP terminal typeSupported SIP terminal typesSIP server

SIP server — the SIP-terminal acts as a server, any SIP-clients can be connected to it

SIP client — the SIP-terminal acts as a client, it can be connected to any SIP-server

The Basic settings tab

Table describes the parameters of the Basic settings tab.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The Network drop-down listIs selected in the list

Sets the IP address of the network adapter that will be used to connect to the network where the SIP-clients are located.

IP-addressDefault network adapterThe list of available network adapters
2The SIP port fieldEnter the value in the field

Sets the port number which will receive the data from the SIP-clients

Integer50600-65535
3The SIP transport drop-down listIs selected in the list

Sets the transport level protocol to be used.

Supported transport level protocolsUDP

TCP

UDP

4The RTP ports range, from and to fieldsEnter the value in the field

Sets RTP ports range

Integer

from: 40000

to: 64000

0-65535
5The Address fieldEnter the value in the field

For SIP-client terminal type only

Sets the IP address of the SIP-server

IP-address-1.0.0.0 - 255.255.255.255
The Port fieldEnter the value in the field

For SIP-client terminal type only

Sets the port for the SIP-server connection

Integer-0-65535

The Advanced settings tab

Table describes the parameters of the Advanced settings tab.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The Subscriber fieldEnter the value in the fieldSets the SIP server special numberInteger->=0
2The Name fieldEnter the value in the fieldSets the name of the special numberLatin, Cyrillic letters and service characters-A line representing a sequence of any symbols

The Numbers settings tab

Table describes the parameters of the Numbers settings tab.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The Subscriber column AutomaticallyLists the numbers of all devices and operators registered on the SIP-terminal, as well as special numbers.---
2The Name fieldAutomaticallyLists the names of the corresponding devices, operators, and special numbers.---
3The Redirecting fieldEnter the value in the fieldSets the number to which the corresponding subscriber's calls should be forwarded to.Integer-Numbers of all devices and operators registered on the SIP-terminal, as well as special numbers.
4The Pending, sec fieldEnter the value in the fieldSets the time period in seconds, during which it is necessary to wait for a response from the subscriber.Integer->0
5The One responder checkboxSet the checkboxEnables a group call (redirected to several numbers) ending after one of the recipients answersBoolean typeNo

Yes – a group call is ended at all recipients after the response of any operator or device.

No – the group call is not ended after the answer of the first or subsequent operators and/or devices, i.e. all recipients can join the call.

6The Run macro drop-down listIs selected in the listSets the Macro object which should be run when calling the subscribe.

Name of the Macro objects

registered in the system.

-Depends on the number of the Macro objects in the system.
7The Calling number multicast (video) fieldEnter the value in the fieldSets the IP address for broadcasting the video stream from the calling device in the multicast mode.IP-address-1.0.0.0 - 255.255.255.255
8The Calling number multicast (audio) fieldEnter the value in the fieldSets the IP address for broadcasting the audio stream from the calling device in the multicast mode.IP-address-1.0.0.0 - 255.255.255.255
9The Destination number multicast (video) fieldEnter the value in the fieldSets the IP address for broadcasting the video stream from the destination device in the multicast mode.IP-address-1.0.0.0 - 255.255.255.255
10The Destination number multicast (audio) fieldEnter the value in the fieldSets the IP address for broadcasting the audio stream from the destination device in the multicast mode.IP-address-1.0.0.0 - 255.255.255.255
  • No labels