The settings panel of the SIP-operator object is shown in the pictures below.

Table describes the parameters of the SIP-operator system object.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1

The Number field

Automatically

Sets the identification number for calls

Sequence of numbers

-

>=0

2The Bind operator to user rights checkboxIs set with a checkbox

Enables binding of a SIP-operator to Axxon PSIM user rights. Activates the User drop-down list.

Note. It is used when the User rights are selected by default on the operator's SIP panel.



Yes - binding of a SIP-operator to Axxon PSIM user rights is enabled

No - binding of a SIP-operator to Axxon PSIM user rights is disabled

3The User drop-down listIs selected in the listSets the user under which it is necessary to register in Axxon PSIM.

Name of the User objects registered in the system.


Depends on the number of the User objects in the system.
4The Device priority drop-down listIs selected in the listSets the priority of a call from this operator in the incoming calls window of the SIP panel.Sequence of numbersNo

0 – 10

The lower the number, the higher the priority and, accordingly, the higher the display in the list.

If the field is left blank, then the priority is considered to be minimal.

Calls from operators with the same priority will be sorted by the time of the call.

The Server connection tab (only for SIP client terminal type)

Table describes the parameters of the Server connection tab.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The Login fieldEnter the value in the fieldSets the username for connecting to the SIP-serverLatin, Cyrillic letters and service characters-A line representing a sequence of any symbols (letters, numbers, service symbols)
2The Password fieldEnter the value in the fieldSets the password for connecting to the SIP-serverLatin, Cyrillic letters and service characters-A line representing a sequence of any symbols (letters, numbers, service symbols)

The Address book tab

Table describes the parameters of the Address book tab.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The Address books tableIs selected in the columnSets the list of address books, the numbers of which should be available for this SIP-operator--

-

The Number columnIs selected in the listSelecting the address book identifierIdentifiers of Address book objects registered in the system-Depends on the number of Address book objects in the system
The Name columnIs selected in the listSelecting the name of the address book in Axxon PSIMNames of Address book objects registered in the system-Depends on the number of Address book objects in the system
2The All buttonClick the buttonAdds all existing address books to the table---
3The Range buttonClick the buttonOpens the Add address books window to add multiple address books---