The settings panel of the Telemetry control panel object is shown in the figure.

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Telemetry control panel object.

Parameter

Method for setting the parameter

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Telemetry control panel object in the system.

Sequence of numbers

-

1 or more

Depends on the Telemetry control panel objects in the system.

2

Name*

Type-in the value in the field

Specifies the name of the Telemetry control panel object in the system.

Latin, Cyrillic and service characters

Telemetry control panel

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Checkbox is set

Sets the status of the Telemetry control panel object in the system.

Boolean type

-

Yes – the Telemetry control panel object is disabled and is not in use

No – the Telemetry control panel object is enabled and is in use.

4

Display

Is selected in the list

Sets the parent Display object for the given Telemetry control panel object.

Names of the Display objects registered in the system

Name of the parent Display object.

Depends on the number of the Display objects in the system.

The Coordinates group

5

Monitor

Is selected in the list

The number of monitor in OS for which coordinates are specifying

Numbers of monitors

1

1-16

6

X

Type-in the value in the field.

Sets the coordinate in the X horizontal axis for the upper left corner of the Telemetry control panel on the screen.

% of the screen width.

   30

From 0 to M*100, where M is the number of monitors installed.

7

Y

Type-in the value in the field.

Sets the coordinate in the Y vertical axis for the upper left corner of the Telemetry control panel on the screen.

% of the screen height.

30

From 0 to M*100, where M is the number of monitors installed.

8

W

Type-in the value in the field.

Sets the width of the Telemetry control panel.

% of the screen width.

   -

From 18 to M*100, where M is the number of monitors installed.

9

H

Type-in the value in the field.

Sets the height of the Telemetry control panel

% of the screen height.

-

From 34 to M*100, where M is the number of monitors installed.

10

Current settings*

Click the button

Sets the current coordinates of the Telemetry control panel in X, Y, W and H fields

-

-

-

11

Allow window’s moving

Checkbox is set

Allows moving the Telemetry control using the mouse panel

Boolean type

Yes

Yes – allow moving the Telemetry control panel

No – forbid moving Telemetry control panel

12

Half-transparent window

Checkbox is set

Displays the half-transparent Telemetry control panel

Boolean type

Yes

Yes- display the half-transparent Telemetry control panel.

No – do not display the half-transparent Telemetry control panel.

13

Priority

Is selected in the list

Sets the priority of Telemetry control

Names of priorities for Telemetry control

Low

Forbidden – Telemetry control is forbidden.

Low – control over PTZ device using the Telemetry control panel is performed after it controls devices with Standard or High ptiority

Standard - control over PTZ device using the Telemetry control panel is performed after it controls devices with High ptiority.

High - control over PTZ device using the Telemetry control panel is performed in the first place

14

Allow presets

Checkbox is set

Enables saving presets

Boolean type

Yes

Yes – presets saving is enabled.

No  – presets saving is disabled

15

Allow hotkeys

Checkbox is set

Enables Telemetry control using a keyboard

Boolean type

No

Yes– keyboard can be used for Telemetry control

No – keyboard hotkeys are not used for Telemetry control  

16

Available cameras with telemetry control

Automatically

Shows cameras with PTZ devices.

Names of the Camera objects registered in the system.

The list of all Camera objects registered in the system.

Depends on the number of PTZ devices.

17

Selected cameras

Click arrow keys

Shows cameras with PTZ devices that can be controlled using the Telemetry control panel

-

-

Depends on the number of PTZ devices.

18

One to the right*

Click the button

Moves specified PTZ device from the Available cameras with telemetry control list to the Selected cameras list

-

-

-

19

One to the left*

Click the button

Moves specified PTZ device from the Selected cameras list to the Available cameras with telemetry control list.

-

-

-

20

All to the right*

Click the button

Moves all PTZ devices from the Available cameras with telemetry control list to the Selected cameras list.

-

-

-

21

All to the left*

Click the button

Moves all PTZ devices from the Selected cameras list to the Available cameras with telemetry control list.

-

-

-

*  The name of the element is not displayed in the settings panel of the given object