The Intellect section is used for Intellect advanced setup. The settings panel for the Intellect section is shown in the figure.

 

The parameters of the Intellect settings panel are described in the table.

No

Parameter name

Field type

Description

Representation

Default value

Value range

1

The Core IP address field with  button. Is set on the Client

Type-in the value in the field/use the  button

Sets the IP address of the Intellect server to which the slave.exe module is connected by default.

In case of pressing button, IP address of the local computer is set


IP address

127.0.0.1

Depends on net settings of the Server. In case of connection failure dialog window requiring IP address is displayed

2

Keyboard prefix

Type-in the value in the field

Sets the prefix for a special key-board. When a button is pressed on this key-board the Intellect detects when the button was pressed on this very key-board

Symbol

Usually, a tilde (~), code 126

The Logging subsystem group

3

Debug mode

Drop-down list item

Sets the mode of the Intellect  Debug window displaying


List of available modes of Debug window displaying

None


DisabledDebug window is not displayed.

Debug 1Debug window is displayed  and a log-file containing recordings about modules errors is created.

Debug 2Debug window is displayed and a log-file containing recordings about modules errors and alerts is created.

Debug 3Debug window is displayed and a log-file containing recordings about all the modules events is created.

Debug 4Debug window is displayed and a log-file containing recordings about all the modules events, and also additional menu that is individual for each module (used by programmers) are created

4

Log-storing time (hours)

Type-in the value in the field

Sets the time of keeping log files

Sequence

48 hours

> 0

5

Counters logging time (sec)

Type-in the value in the field

Assigns the time interval in seconds for logging processor load, memory usage, and disk usage

Sequence

60

Positive whole numbers not less than 60 and zero. If the value 0 is specified, sensor data is not included in the log file

6

Save logs

Checkbox

Enables logs saving

Boolean type

Yes

Yes—logs are saved.

No—logs are not saved

7

Redirect to debugger

Checkbox

Enables the debugger

Boolean type

None

Yes—the debugger is in use.

No—the debugger is not in use

8

Maximum size (MB)

Type-in the value in the field

Defines the maximum size of RAM that log files can use. Log files are archived after that size is reached

Sequence

100 MB

>= 100

Values less than 100 Mb are ignored

The JPG and AVI files export path group

9

Default (Intellect\Export)/Other

Set in the position

Sets the folder for exported frames from the Intellect video archive (see Frame export)


Default (Intellect\Export)


Default (Intellect\Export)—exported to the C:\Users\%current user name%\Documents\Intellect\export\ folder

Other—exported to the selected folder

10

Other with the button

Click the button/type-in the value in the field

Sets the path name to the folder, where frames from video archive are to be exported when the switch is set in the Other position.

Note. The specified path will be applied to the ExportDir registry key located in HKLM\SOFTWARE\WOW6432Node\AxxonSoft\Intellect\Video (see Registry keys reference guide)

Path name

11

Open folder

Click the button

Opens the current folder for frame export

12Record pathCheckbox

The checkbox allows you to prohibit changing the export directory when exporting a frame

Boolean typeNo

Yes—export catalogue change is forbidden.

No—export catalogue change is allowed

No group

13

Receive uncompressed video

Checkbox

Enables receiving uncompressed video from the Server. As a rule is set on the Client

Boolean type

No

Yes—Client receives uncompressed video from the Server

No—Client receives compressed video from the Server

14

Event viewer over all windows

Checkbox

Enable displaying the Event viewer window over all windows

Boolean type

No

Yes—the Event viewer window is displayed over all windows.

No—the Event viewer  window is displayed if a corresponding screen is selected

15

Only local protocol

Checkbox

Enables logging the events registered in the given computer to the Events protocol database.

Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section

Boolean type

No

Yes—events registered in the given computer are recorded to the Events protocol database

No—all required events are recorded to the Events protocol database

16Sort tree objects by IDCheckbox

Enables sorting of objects in the tree by identifier.

Note 1. If sorting by name is chosen, and there are numbers in the object name, then the objects will be sorted in alphabetical order. For example, an object with the name "115" will be above the object with the name "15", because in the name "115" the second number is 1, and in the name "15" the second number is 5.

Note 2. This key also affects the sorting of objects in the tree when adding the objects to a layer in the Map Editor utility

Boolean typeNo

Yes—objects in the tree are sorted by identifier

No—objects in the tree are sorted by name

17

Disable protocol

Checkbox

Disables events logging to the Event viewer database on this computer.

Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section

Boolean type

No

Yes—events are not logged to the Event viewer database

No—events are logged to the Event viewer database

18

Used memory dump

Checkbox

Enables logging .dmp file with a copy of main memory with incorrect shutting down at least one of the system modules to the Intellect root folder

Boolean type

No

Yes—memory dump is created

No—memory dump is not created

19

Support old scripts

Checkbox

Sets the support of program tools in Intellect

Boolean type

No

Yes—both scripts and programs are supported

No—only scripts are supported


20

Time synchronization

Checkbox

Sets the time synchronization of all computers in the distributed system with system time of this computer. Time is automatically synchronized at midnight every 24 hours or when Intellect is started on the Server that is the source of time synchronization

Boolean type

No

Yes—synchronization is enabled

No—synchronization is disabled


21

Overlay in Event protocol

Drop-down list item

Sets the overlay mode for processing the video signals that can be viewed with the help of the Event protocol object

Names of overlay modes

Overlay 2

None—video signals are not processed by video card

Overlay 1—Direct3D is used

Overlay 2—DirectDraw is used

22

Application language

Drop-down list item

Sets the Intellect Software System's interface language

Names of installed languages

Depends on the set of installed languages. The process of installing languages is described in Intellect Software System's interface language