Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Current »

The Grabber object corresponds to the Video Capture Device system object.

The Grabber object sends events presented in the table. Procedure is started when the corresponding event appears.

Format of events procedure for the video capture device:

OnEvent("GRABBER","_id_","_event_")

Description of events of the Grabber object.

Event

Description

"+12V"

Voltage error +12V

"+3.3V"

Voltage error +3.3V

"+5V"

Voltage error +5V

"-12V"

Voltage error -12V

"-5V"

Voltage error -5V

"CPU_FAN"

Number of ventilator rotations

"CPU_TEMP"

Temperature of processor

"SYS_TEMP"

Temperature of MB chipset

"UPS_COMMLOST"

Connection lost

"UPS_FATAL_ERROR"

Error of connection

"UPS_LOWBATT"

Battery low

"UPS_ONBATT"

Switch to battery supply

"UPS_ONLINE"

Restoring the main supply

"UPS_REPLACEBATT"

Battery changing is required

"UPS_SHUTTING"

Shutdown

"VCORE"

Voltage of processor core

"AUDIO_SIG_LOST"

Sound lost

"CONNECT_FAIL"

Connection error

"CONNECT_OK"

Connected

"NETWORK_FAILURE"

Connection lost

"STATE_CONNECTED"

Connection restored

Operator format to describe actions with the video capture device is:

DoReact("GRABBER","_id_","_command_" [,"_parameters_"]);

List of commands and parameters for the Grabber object is presented in the following table:

Commandcommand description

Parameters

Description of parameters

"SETUP" – sets parameters of video capture device

chan<>

Number of PCI slot (0,1,2,…,32)

mode<>

Speed of grabber/digitising (0 – maximal, 1 – average, 2 – minimal)

resolution<>

Resolution (0– standard, frame quarter (384x288); 1 – high, half-frame (768x288); 2 – maximal frame (768x576))

format<>

Format of video signal (PAL, NTSC)

drives<>

Disks for video archive record (DRIVE1:\, DRIVE2:\ … DRIVEN:\)

cams<>

Number of connected video cameras

auth<>


ip<>

IP-address of video input network card

name<>

Name of object

flags <>

Flags

ip_port<>

IP-port

password<>

Password

type<>

Type of digitising

username<>

Login

watchdog<>

WatchDog shutdown (0 – disabled, 1 – enabled)

"SET_DRIVES" – sets disks for video archive record

drives<>

Disks for video archive record

"MUX1_OFF" – disables video output through the analog output 1

-

-

"MUX2_OFF" – disables video output through the analog output 2

-

-

"MUX3_OFF" – disables video output through the analog output 3

-

-

"SET_IPINT_PARAM" – Sets (change) parameters of IP-device. Reaction allows changing of IP-device settings not entering its web-interface.

Note. For reaction operation it is required to enable the mode of multi-flow video signal - see. Administrator's Guide, section Configuration of multistream video, and Appendix 2. Defining the param_id and param_value values for the SET_IPINT_PARAM reaction




param_id<>

Name of parameter. Set of parameters for each camera is individual - see Appendix 2. Defining the param_id and param_value values for the SET_IPINT_PARAM reaction

param_value<>

Value of parameter. Set of parameters for each camera is individual - see Appendix 2. Defining the param_id and param_value values for the SET_IPINT_PARAM reaction

cam_id<>

Camera ID in the Axxon PSIM software package

vstream_id<>

Number of video-flow (optional parameter). Is given by “Number of camera”. ”Number of flow”, for example 1.1, 1.2

"START" – start playing video file in a virtual video capture device--
"STOP" – stop playing video file in a virtual video capture device--
"ENABLE" – enable object (uncheck the Disable box in the object settings panel)recursive<>

Possible parameter values:

0 – enable only Video capture device

1 – enable the Video capture device and all Camera objects created under it

"DISABLE" – disable object (check the Disable box in the object settings panel)recursive<>

Possible parameter values:

0 – disable only Video capture device

1 – disable the Video capture device and all Camera objects created under it

Properties of the GRABBER object are shown in the table.

Properties of the GRABBER object

Description of properties

ID<>

Object ID

PARENT_ID<>

Number of video capture device

Examples of using events and reactions of the Video capture Device object:

  1. It is required to set the first channel for the first video capture device, maximal speed of digitizing, resolution is half-frame and PAL format while starting the first macro.

    OnEvent("MACRO","1","RUN") // start macro 1
    {
     DoReact("GRABBER","1", "SETUP", "chan<1>,mode<0>,resolution<1>,format<PAL>");
     //set channel 1 for the first video capture device, speed of digitizing is maximal, resolution is half-frame, format is PAL
    }

    Note.

    Description of the MACRO object is follows (see the MACRO section).
  2. Set disks D:\ and F:\  for video archive record while starting the third macro.

    OnEvent("MACRO","3","RUN") //start macro 3
    {
     DoReact("GRABBER","1","SET_DRIVES","drives<D:\,F:\>"); //record the video archive on disks D:\ and F:\
    }
  3. It is required to display the first video camera on the first analog output and disable first analog outputs of the first and second cards while error of connection to the second video capture device.

    OnEvent("GRABBER","2"," UPS_FATAL_ERROR") //error of connection to the video capture device 2
    {
     DoReact("CAM","1","MUX1"); //display video camera 1 on the 1-st analog output of card
     Wait(5);
     DoReact("GRABBER","1","MUX1_OFF"); //disable 1-st analog output of the first card
     DoReact("GRABBER","2","MUX1_OFF"); //disable 1-st analog output of the second card
    }

    Note.

    If analog outputs of two or more cards are connected in parallel and video camera 1 belongs to the first grabber and video camera2 belongs to the second grabber than while triggering the «DoReact("CAM","1","MUX1");» command it is required to trigger the «DoReact("GRABBER","2","MUX1_OFF");» command at first, and correspondingly while triggering the «DoReact("CAM","2","MUX1");» command it is required to trigger the «DoReact("GRABBER","1","MUX1_OFF");» command at first. Otherwise signal overlaying will happened.

    Note.

    Description of the CAM object is follows (see the CAM section).
  4. It is required to disable the second analog output of the video capture device while restoring the main supply.

    OnEvent("GRABBER","1","UPS_ONLINE") //restoring the main supply
    {
     DoReact("GRABBER","1","MUX2_OFF"); //disable analog output 2
    }
  • No labels