The GRAY object corresponds to the Sensor system object.

The GRAY object sends events presented in the table. Procedure is started when the corresponding event appears.

Format of events procedure for the sensor:

OnEvent("GRAY","_id_","_event_")

 

Event

Description

"ALARM"

Alarm. This event is received while opening or closing the sensor (it depends on object settings) if sensor is armed. If sensor is disarmed then Sensor opened and Sensor closed events are received correspondingly

"ARM"

Sensor is armed

"CONFIRM"

Alarm received

"DISARM"

Sensor is disarmed

"NOT_VALID_STATE"

Zone is not ready

"OFF"

Sensor opened. This event is received while sensor opening if sensor is disarmed

"ON"

Sensor closed. This event is received while sensor closing if sensor is disarmed

"SIGNAL_LOST"

Connection with sensor is lost

Operator format to describe actions with the sensor is:

DoReact("GRAY","_id_","_command_");

List of commands and parameters for the GRAY object is presented in the following table:

Commandcommand description

Parameters

Description

"ARM" – arm sensor.

-

-

"DISARM" – disarm sensor.

-

-

“CONFIRM” – confirm alarm.

-

-

“SETUP” – settings for sensor.

chan<>

Output number (0 – 15)

flags<>

Flags

name<>

Object name

type<>

Type of sensor object (0 – on closing, 1 – on opening)

Properties of the GRAY object are shown in the table.

Properties of the GRAY object

Description of properties

ID<>

Object ID

PARENT_ID<>

Parent object ID

REGION_ID<>

Region ID

Check function of the GRAY object state:

CheckState ("GRAY","number","state")

The GRAY object can be in the following states:

State of the GRAY object

State description

"ARMED"

Sensor is armed

"DISARME"”

Sensor is disarmed

"ALARMED"

Alarm

"CONFIRMED"

Alarm confirmed

"DISARMED_ALARM"

Not ready

"DETACHED_ARMED"

Connection lost

"DETACHED_DISARM"

Connection lost

“OFF”

Normal

 Examples of using events and reactions of the Sensor object:

  1. It is required to switch over the second sensor to the second input if connection with the first sensor is lost.

    OnEvent("GRAY","1"," SIGNAL_LOST") //connection with first sensor is losst
    {
     DoReact("GRAY","2","SETUP","chan<2>"); //sensor is on the second input
    }
  2. Open the second sensor and enable the rollback record of the first video camera in case of the first sensor is closed.

    OnEvent("GRAY","1"," ON") //first sensor is closed
    {
     DoReact("GRAY","2","SETUP","type<1>"); //open the second sensor
     DoReact("CAM","1","REC","rollback<1>");//perform rollback record from the first video camera
    }