Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

VMS logs every ANPR number (see System log).

Attention!

Depending on detection tool settings, a delay may occur between the number recognition and the registration of the corresponding event (see Configuring the License Plate Recognition VT, Configuring the License Plate Recognition IV).

The event is time-stamped with the time of recognition, not registration.

For example, if a car passes the camera at 12:05:00, and the detection tool is set to a 10 sec timeout, the event will be registered at 12:05:10 and the event data will include 12:05:00 as the time of recognition.

Attention!

The standard license provides a more than 30-sec delay between the number recognition and the corresponding event (see Configuring the License Plate Recognition VT.

All relevant events can be displayed on the Event Board (see Working with Event Boards) or Dialog Board (see Working with Dialog Board).

If you have created any LP lists in your system, you can program automatic responses (e.g. alarm triggering) to LP recognition events related to list's entries (see Configuring vehicle license plate recognition based on the created lists).

  • No labels