Go to documentation repository
Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.
Previous page Next page
This action checks recorded video from a specific camera or group of cameras for the specified period.
To configure this action, do the following:
- Configure the conditions to start a macro (see Configuring start conditions).
Select a camera or a group of cameras to check if there is a record in the archive (1).
Attention!
If a macro is started by an event from an input or output (see Configuring start conditions) that is not connected to any camera, you need to select a specific camera here. If you select a group of cameras or a camera that initiated the command, the action doesn't start.
- Select an archive where you want to check if recorded video is available (2). If you leave the field empty, all recorded video in this camera archives will be checked.
- Specify the depth of check (3). The check time period covers: [the time of the action start - (minus) the depth of the check; start time of the action].
- Select an action if the archive record for the specified period is found (4).
- Select an action if the archive records for the specified period are not found (5).
Note
If E-mail notification is selected as an action, then the text of the message will contain cameras (if a group of cameras was selected), for which there is no record in the archive for the specified period.
You can also use two special purpose templates in the message:
- {failureRecordCheck}—failed check of a record in the archive (format: Server Name|Camera Name|Archive Name);
- {successRecordCheck}—successful check of a record in the archive (format: Server Name|Camera Name|Archive Name).
Attention! For the correct execution of the macro, synchronize the time across all Servers within the Axxon-domain.