Go to documentation repository
Previous page Next page
The settings panel of the State statistics interface object is shown in the figures.
The table describes the setting parameters of the State statistics interface object.
The Filters tab
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Filters tab | ||||||
1 | Identification number* | Automatically | Displays the identification number of the State statistics object in the system | Numbers, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the State statistics objects in the system |
2 | Name* | Enter the value in the field | Sets the name of the State statistics object in the system | Latin, Cyrillic, and service characters | State statistics | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the chechbox | Disables the State statistics object in the system | Boolean type | Clear | Set—the State statistics object is disabled and isn't used Clear—the State statistics object is enabled and used |
4 | Display | Select the value from the list | Sets the Display parent object to which the given State statistics object belongs | Names of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the system |
The Position group | ||||||
5 | X | Enter the value in the field | Sets the X coordinate in the horizontal axis for the upper left corner of the State statistics window | % of the screen width | NA | From 0 to M*100, where M is the number of the installed monitors |
Y | Enter the value in the field | Sets the Y coordinate in the vertical axis for the upper left corner of the State statistics window | % of the screen height | NA | From 0 to M*100, where M is the number of the installed monitors | |
6 | W | Enter the value in the field | Sets the width of the State statistics window | % of the screen width | NA | From 0 to M*100, where M is the number of the installed monitors |
H | Enter the value in the field | Sets the height of the State statistics window | % of the screen width | NA | From 0 to M*100, where M is the number of the installed monitors | |
The button
| Click the button | Opens the window for changing the size and position of the State statistics window | NA | NA | NA | |
7 | Allow moving | Set the checkbox | Allows moving the State statistics window manually using the mouse | Boolean type | Clear | Set—allow moving the State statistics window manually using the mouse Clear—disable moving the State statistics window manually using the mouse |
8 | Monitor | Select the value from the list | Sets the number of the monitor in the system for which the coordinates are specified | Numbers of the monitors in OS | 1 | From 1 to 16 |
The Objects group | ||||||
9 | Type | Select the value from the list | Sets the type of the objects whose events must be displayed in the State statistics window | Available object types | NA | Depends on the objects registered in the system. You can select only those object types that have the "INFORMATION" or "ALARM" value selected in the Processing messages column on the Events tab of the ddi.exe utility (see The Events tab) |
10 | Event type | Select the value from the list | Sets the events that must be displayed in the State statistics window | Events available for the selected object | NA | Depends on the object type |
11 | Color | Select the value from the list | Sets the color of the state displayed in the table and on the graph in the State statistics interface window | Color palette | Black | RGB color |
Out of the group | ||||||
12 | Number of pixels | Enter the value in the field | Sets the number of pixels to be displayed on the State statistics graph | Integer numbers | 0 | >=0 |
The DB tab
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
13 | Server | Enter the value in the field | Sets the name of the database server where the required database is stored | Latin, Cyrillic, numbers, and service characters | Name of the server used by the system | Depends on the number of servers in the system |
14 | Folder | Enter the value in the field | Sets the name of the database where the events must be stored | Latin, Cyrillic, numbers, and service characters | Name of the main database used by the system | Depends on the number of databases used by the system |
15 | User | Enter the value in the field | Sets the username to authorize on the database server | Latin, Cyrillic, numbers, and service characters | NA | NA |
16 | Password | Enter the value in the field | Sets the password to authorize on the database server | Latin, Cyrillic, numbers, and service characters | NA | NA |
17 | Connection dialog | Click the button | Opens the window to connect the database server | NA | NA | NA |
The Interface tab
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
18 | Font | Click the button | Opens the dialog window for setting the text font for the table and the graph (except for the legend—a short list or table with data) in the State statistics window | NA | NA | NA |
*Name of the element isn't displayed in the settings panel of the given object.