Documentation for Axxon PSIM 2.0. Documentation for other versions of Axxon PSIM is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

The settings panel of the State statistics interface object is shown in the figures.

The table describes the setting parameters of the State statistics interface object.

The Filters tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Filters tab

1

Identification number*

Automatically

Displays the identification number of the State statistics object in the system

Numbers, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the State statistics objects in the system

2

Name*

Enter the value in the field

Sets the name of the State statistics object in the system

Latin, Cyrillic, and service characters

State statistics

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the chechbox

Disables the State statistics object in the system


Boolean type

Clear

Setthe State statistics object is disabled and isn't used

Clearthe State statistics object is enabled and used

4

Display

Select the value from the list

Sets the Display parent object to which the given State statistics object belongs

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the system

The Position group

5


X

Enter the value in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the State statistics window

% of the screen width

NA

From 0 to M*100, where M is the number of the installed monitors

Y 

Enter the value in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the State statistics window

% of the screen height

NA

From 0 to M*100, where M is the number of the installed monitors

6

W

Enter the value in the field

Sets the width of the State statistics window 

% of the screen width

NA

From 0 to M*100, where M is the number of the installed monitors

H

Enter the value in the field

Sets the height of the State statistics window 

% of the screen width

NA

From 0 to M*100, where M is the number of the installed monitors

The  button

 

Click the button

Opens the window for changing the size and position of the State statistics window

NA

NA

NA

7

Allow moving

Set the checkbox

Allows moving the State statistics window manually using the mouse

Boolean type

Clear

Setallow moving the State statistics window manually using the mouse

Cleardisable moving the State statistics window manually using the mouse

8MonitorSelect the value from the list

Sets the number of the monitor in the system for which the coordinates are specified

Numbers of the monitors in OS1From 1 to 16

The Objects group

9TypeSelect the value from the list

Sets the type of the objects whose events must be displayed in the State statistics window

Available object typesNA

Depends on the objects registered in the system.

You can select only those object types that have the "INFORMATION" or "ALARM" value selected in the Processing messages column on the Events tab of the ddi.exe utility (see The Events tab)

10Event typeSelect the value from the listSets the events that must be displayed in the State statistics windowEvents available for the selected objectNADepends on the object type
11ColorSelect the value from the list

Sets the color of the state displayed in the table and on the graph in the State statistics interface window

Color paletteBlackRGB color

Out of the group

12

Number of pixelsEnter the value in the fieldSets the number of pixels to be displayed on the State statistics graphInteger numbers0>=0

The DB tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
13ServerEnter the value in the fieldSets the name of the database server where the required database is storedLatin, Cyrillic, numbers, and service charactersName of the server used by the systemDepends on the number of servers in the system
14FolderEnter the value in the fieldSets the name of the database where the events must be storedLatin, Cyrillic, numbers, and service charactersName of the main database used by the systemDepends on the number of databases used by the system
15UserEnter the value in the fieldSets the username to authorize on the database serverLatin, Cyrillic, numbers, and service charactersNANA
16PasswordEnter the value in the fieldSets the password to authorize on the database server Latin, Cyrillic, numbers, and service charactersNANA
17Connection dialog Click the buttonOpens the window to connect the database serverNANANA

The Interface tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
18FontClick the buttonOpens the dialog window for setting the text font for the table and the graph (except for the legend—a short list or table with data) in the State statistics windowNANANA

*Name of the element isn't displayed in the settings panel of the given object.

  • No labels