Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 23 Next »

The Security zone object is used for the general configuration of Axxon PSIM.

The settings panel of the Security zone object is shown in the figures with tabs. The tables describe the settings.

The Basic settings tab:

 

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1The Protocol clear time fieldEnter the value in the field using the up and down buttonsSets the time of the day at which to start cleaning up the Event Viewer database according to the Events archive length parameterHH:MM:SSCurrent system time at the moment of opening the object settings panelFrom 00:00:00 to 23:59:59

2

The Events archive length days
field

Enter the value in the field

Sets the number of days to store information about the events registered by Axxon PSIM and recorded into both the Event Viewer and the Incident server. This parameter affects all computers in a distributed system

Days

3

From

3

The Object code field

Enter the value in the field

Sets the number of the access control card, which is automatically displayed in the settings panel of the User object when the object is created in the Object code field

Sequence of numbers

NA

More than 1

4

The Starting configuration 
drop-down list

Select the value from the list

Sets the macro, which runs automatically when starting Axxon PSIM 

Names of the Macro objects registered in the system

NA

Depends on the number of the Macro objects created in the video surveillance system with distributed architecture

5

The Connections in architecture checkbox

Set the checkbox

Sets the computers with which the Computer object must exchange the data about the system configuration parameters: with all computers in the video surveillance system with distributed architecture or only with the Computer object on the basis of which the given object is created

Boolean type

Clear

Setwhen you create a new computer, the Connection checkboxes on the Architecture tab are set for all computers in the architecture

Clearwhen you create a new computer, the Connection checkbox on the Architecture tab is set only for the computer from which this new object is created

6

The DNS instead of IP allowed
checkbox

Set the checkbox

Sets the address of the server/Remote Administrator’s workstation/Remote client on the Architecture tab as DNS name, not only IP address

Boolean type

Clear

Set—when you configure the interaction of the computers in the distributed system, you can specify the DNS name of the server/Remote Administrator’s workstation/Remote client instead of its IP address on the Architecture tab. At the same time, the verification of the entered address is disabled

Clear—when you configure the interaction of the computers in the distributed system, specify the IP address of the server/Remote Administrator’s workstation/Remote client on the Architecture tab

7The Ping (s) fieldEnter the value in the field

Sets the check period for the computer connection to the server

Note. For servers, this value is saved automatically in the CheckPingPeriod parameter. For the Remote client, you can specify the value manually in the CheckPingPeriod parameter (see Registry keys reference guide)

Sequence of numbers10>=1
8The Show documentation by clicking F1
checkbox
Set the checkboxEnables opening documentation in the pdf format by pressing the F1 button when Axxon PSIM is running. The Administrator's Guide section is opened on the server and the Remote Administrator's workstation; the Operator's Guide section is opened on the Remote clientBoolean typeClear

Set—the documentation is displayed by pressing the F1 button

Clear—the feature of displaying the documentation by pressing the F1 button is disabled

9The Debug statistics button Click the buttonOpens the window with the events queue statisticsNANANA
10The Administrator’s password 
button
Click the buttonOpens the Set password window used for changing the administrator’s passwordNANANA

11


The Internal synchronization: offline
checkbox

Set the checkbox

Enables the offline synchronization of events

Boolean type

Set

Set—the offline synchronization is enabled. When the computer is reconnected, it gets all events for the no-connection time period

Clear—the offline synchronization is disabled. When the computer is reconnected, it doesn't get the events for the no-connection time period

The Internal synchronization: online
checkbox

Set the checkbox

Enables the online synchronization of events

Boolean type

Set

Set—the online synchronization is enabled. Events are sent right after they occur according to the configuration parameters of the computer interaction in the distributed system

Clear—the online synchronization is disabled. Events aren't sent

The Holidays group*

12

The Holidays field

Automatically

Displays the list of calendar days which are determined as holidays in Axxon PSIM

List of dates.

Date format: DD-MM-YY

NANA

13

The Add button

Click the button

Opens the Calendar window to select the date of a new holiday

NA

NA

NA

14

The Delete button

Click the button

Deletes the selected holiday date from the holidays list

NA

NA

NA

15

The Edit button

Click the button

Opens the Calendar window to change the date of the selected holiday in the list

NA

NA

NA

Out of the group
16The SMS confirmation
drop-down list
Select the value from the listSets the Short Message object for the two-factor authentication—see Configuring two-factor authenticationNames of the Short Message objects registered in the systemNADepends on the number of the Short Message objects created in the system

*Name of the element isn't displayed in the settings panel of the given object

The Date and time format tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

17The Date format
drop-down list
Select the value from the list

Sets the format of the date that is displayed in the Incident manager, Operator protocol, and Video surveillance monitor in the current date field and when you work with the archive

List of types of date formatCurrent
  • Current—the date format set in the OS;
  • dd/MM/yy—the day/month/year format;
  • MM/dd/yy—the month/day/year format;
  • yyyy-MM-dd—the year/month/day format
18The Time format
drop-down list
Select the value from the listSets the format of the time that is displayed in the Incident manager, Operator protocol, and Video surveillance monitor in the current date field and when you work with the archiveList of types of time formatCurrent
  • Current—the time format set in the OS;
  • HH:mm:ss24-hour format;
  • hh:mm:ss tt12-hour format

The RabbitMQ tab

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

19The Server
field
Enter the value in the fieldSets the RabbitMQ server addressLatin alphabet, numbers, and service characterslocalhostServer IP address or name
20The Port
field
Enter the value in the fieldSets the RabbitMQ server portNon-negative integersNA

From 0 to 65535

If the port is 0 or not specified, RabbitMQ won't run

21The User
field
Enter the value in the fieldSets the RabbitMQ server usernameLatin alphabet, numbers, and service charactersguestDepends on the registered RabbitMQ users
22The Password
field
Enter the value in the fieldSets the RabbitMQ server user passwordLatin alphabet, numbers, and service charactersguestDepends on the registered RabbitMQ users
23The Content-type
drop-down list
Select the value from the listSets the type of the sent/received contentAvailable types of contentplain/text
  • application/json—a message in JSON format is sent;
  • plain/textThe Axxon PSIM event is sent in the "TYPE|ID|EVENT" format