This action checks if there is at least one recording interval in the archive from a particular camera or a group of cameras for the specified period.
To configure this action, do the following:
If a macro is initiated by an event from an input or output (see Configuring start conditions) that is not connected to any camera, you need to select a specific camera for this action. If you select a group of cameras or a camera that initiated the macro, the action doesn't start. |
If you select E-mail notification as an action, then the text of the message contains cameras (if a group of cameras is selected), for which there is no record in the archive for the specified period. You can also use two special purpose templates in the message:
Attention! For the correct execution of the macro, synchronize the time across all servers within the Axxon-domain. |
Configuration of the Check that archive record exists action is complete.