To configure the antipassback, do the following:
- Create the required regions in Axxon PSIM (see Subdivision of the protected facility into areas and regions).
- On the settings panel of the Apollo AAN object, enable the zonal or temporary antipassback control (see Configuring AAN controller).
- Specify the created regions for the AIM readers in the Entrance to and Exit from fields (see Configuring the AIM readers).
Create an Apollo APB Area object for each AIM reader. Specify the created regions in the Connection with Axxon PSIM region field of the APB Area settings panel (see Configuring APB Area).
Note
It is recommended to leave the remaining settings of the Apollo APB Area object to default.
- Write the current configuration to the AAN controller (see Write configuration to hardware).
- In the Access Manager module, set the Antipassback parameter value to Yes for the required employee (see Specifying user parameters).
Configuring antipassback is complete.