The settings panel of the SIP-panel object is shown in the pictures figures below.

Image Modified

The description of the Table describes the setting parameters of the SIP-panel interface object is shown in the table.

specifying SymbolRange of values
ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Position group

1


The X field

Enter the value in into the field

Sets the X coordinate in the X horizontal axis for the upper left corner of the SIP-panel interface object on the screenwindow

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors installed

TheY field

Enter the value in into the field

Sets the Y coordinate in the Y vertical axis for the upper left corner of the SIP-panel interface object on the screenwindow

% of the screen height

-

From 0 to M*100, where M is the number of the installed monitors installed

2



The W field

Enter the value in into the field

Sets the window width of the SIP-panel interface objectwindow

% of the screen width

-

From 0 to M*100, where M is the number of the installed monitors installed

The H field

Enter the value in into the field

Sets the window height of the SIP-panel interface objectwindow 

% of the screen heightwidth

-

From 0 to M*100, where M is the number of the installed monitors installed

3The X The × buttonClick the button

Opens a test window

to change

for changing the coordinates of the SIP-panel interface

object

window

---
4The Monitor dropdown listSelect in the value from the list

Sets the

system ID

number of the monitor in the system for which the coordinates are

set

specified

IDs Numbers of the monitors in the OS1From 1 to 16

The Basic settings tab.

Image Modified

The table Table describes the parameters of the Basic settings tab.

specifying SymbolRange of values
ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1The Terminal drop-down listSelect in the value from the listSets the SIP-terminal object, which SIP-devices use the SIP-panelName of the SIP-panel objects registered in the system-Depends on the number of the the SIP-panel objects terminal objects in the system
2The Monitor drop-down listSelect in the value from the listSets the the Monitor object corresponding to the Video Surveillance Monitor surveillance monitor to which the video cameras associated with the corresponding SIP-devices are added.Name of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system

The Advanced settings tab.

Image Modified

The table Table describes the parameters of the Advanced settings tab.

ParameterMethod for
specifying
setting the parameter valueParameter description
Symbol
RepresentationDefault value
Range of values
Value range
The Interface behavior group

1

The

Display only when calling

checkbox

Set the checkbox

Displays the SIP-panel

interface object

only

at call

when calling

Boolean type

No

Clear

YesNo

Setthe SIP-panel is only displayed

during call

when calling

Clear

the SIP-panel is always displayed

2
The
New calls to the end
checkbox
Set the checkboxEnables adding new calls to the end of the listBoolean type
No
Clear
Yes

Setnew calls are added to the end of the list

No

Clearnew calls are added to the top of the list

3
The
Disable
 keypress
keypress sound
checkbox
Set the checkbox
Mutes the
Disables keypress sound
of keyspress
on the SIP-panelBoolean type
No
Clear
Yes

Setkeypress sound disabled

No – 

Clearkeypress sound is

turned on

enabled

4
The
Maximize screen on call
checkbox
Set the checkboxEnables automatic display switching
at
on callBoolean type
No
Clear
Yes
Setwhen a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically
No – 

Clearwhen a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen is not displayed automatically

5
The 
Calls to unknown users
 checkbox
Set the checkbox

Enables the option to call unknown

subscribers

users

Note. Unknown user is a number that is present in the SIP-terminal, but not in the address book of the current SIP-operator

Boolean type
Yes
Set
Yes -

Setcalls to unknown

subscribers

users are allowed

No -

Clearcalls to unknown

subscribers are prohibited

users are not allowed

6Switch to incomingSet the checkboxAutomatically switches to the tab of the SIP-panel with the incoming calls, which occurs with incoming calls or call on holdBoolean typeSet

Set—automatic switch to the tab with incoming calls is enabled

Clear—automatic switch to the tab with incoming calls is disabled

The Interface elements group
6
7
The
Dial pad
checkbox
Set the checkboxDisplays the dial pad in the interfaceBoolean type
Yes
Set
Yes -

Setthe dial pad is displayed

No -

Clearthe dial pad is hidden

The
Caption
checkbox
Set the checkboxDisplays the tab names in the interface. When disabled, only the Call tab will be displayed without displaying the nameBoolean type
Yes
Set
Yes -

Setthe tab names are displayed

No -

Clearonly the Call tab is displayed without displaying the name

The
Archive
checkbox
Set the checkboxDisplays the Archive tab in the interfaceBoolean type
Yes
Set
Yes -

Setthe Archive tab is displayed

No -

Clearthe Archive tab is hidden

The
Call control buttons
checkbox
 Set the checkboxDisplays the buttons at the bottom of the panel to control a call
control panel
Boolean type
Yes
Set
Yes -

Setcall control buttons are displayed

No -

Clearcall control buttons are hidden

The Operator settings tab.

Image Modified

The table Table describes the parameters of the Operator settings tab.

ParameterMethod for
specifying
setting the parameter valueParameter description
Presented as
RepresentationDefault value
Range of values
Value range

1

The Operators tableSelect the value in the columnSets the list of the SIP-operators who can work with this SIP-panel---
The
Number
column
Select
in
the value from the listSelects a SIP-operator identifierIdentifiers of
 
the SIP-operator objects registered in the system-Depends on the number
of 
of the SIP-operator objects in the system
The
Subscriber
column
Select
in
the value from the listSelects a SIP-operator numberNumbers of
 
the SIP-operator objects registered in the system-Depends on the number
of 
of the SIP-operator objects in the system
The
Name
column
Select
in
the value from the listSelects a SIP-operator name in Axxon PSIMNames of
 
the SIP-operator objects registered in the system-Depends on the number
of 
of the SIP-operator objects in the system
2
The 
All
 button
Click the buttonAdds all existing SIP-operators to the table---
3
The 
Range
 button
Click the buttonOpens the Add operators window to add multiple SIP-operators---
4
The
Default
drop-down list
Select
in
the value from the listSets the default SIP-operator-Select on start

Select on start

 -

when you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time you will be logged in under the previously selected SIP-operator

User rights

 -

you will log into the SIP-panel as the SIP-operator that is linked to theAxxon PSIM

 

user rights. You should also be logged into Axxon

PSIM 

PSIM with the corresponding user rights

SIP-operator from the list

-

logging into the SIP-panel will be made at once as the selected SIP-operator. Depends on the number

of 

of the SIP-operator objects in the system