Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

The settings panel of the SIP-panel object is shown in the pictures below.

The description of the SIP-panel interface object is shown in the table.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
The Position group

1


The X field

Enter the value in the field

Sets the coordinate in the X horizontal axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The Y field

Enter the value in the field

Sets the coordinate in the Y vertical axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

2



The W field

Enter the value in the field

Sets the window width of the SIP-panel interface object

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The H field

Enter the value in the field

Sets the window height of the SIP-panel interface object

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

3The X buttonClick the buttonOpens a test window to change the coordinates of the SIP-panel interface object---
4The Monitor dropdown listSelect in the listSets the system ID of the monitor for which the coordinates are setIDs of the monitors in the OS1From 1 to 16

The Basic settings tab.

The table describes the parameters of the Basic settings tab.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
1The Terminal drop-down listSelect in the listSets the SIP-terminal object which SIP-devices use the SIP-panelName of the SIP-panel objects registered in the system-Depends on the number of the SIP-panel objects in the system
2The Monitor drop-down listSelect in the listSets the the Monitor object corresponding to the Video Surveillance Monitor to which the video cameras associated with the corresponding SIP-devices are added.Name of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system

The Advanced settings tab.

The table describes the parameters of the Advanced settings tab.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
The Interface behavior group

1

The Display only when calling checkbox

Set the checkbox

Displays the SIP-panel interface object only at call

Boolean type

No

Yesthe SIP-panel is only displayed during call

Nothe SIP-panel is always displayed

2The New calls to the end checkboxSet the checkboxEnables adding new calls to the end of the listBoolean typeNo

Yes – new calls are added to the end of the list

No – new calls are added to the top of the list

3The Disable keypress sound checkboxSet the checkboxMutes the sound of keyspress on the SIP-panelBoolean typeNo

Yes – keypress sound disabled

No – keypress sound is turned on

4The Maximize screen on call checkboxSet the checkboxEnables automatic display switching at callBoolean typeNo

Yes – when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically

No – when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen is not displayed automatically

5The Calls to unknown users checkboxSet the checkbox

Enables the option to call unknown subscribers

Note. Unknown user is a number that is present in the SIP-terminal, but not in the address book of the current SIP-operator

Boolean typeYes

Yes - calls to unknown subscribers are allowed

No - calls to unknown subscribers are prohibited

The Interface elements group
6The Dial pad checkboxSet the checkboxDisplays the dial pad in the interfaceBoolean typeYes

Yes - the dial pad is displayed

No - the dial pad is hidden

The Caption checkboxSet the checkboxDisplays the tab names in the interface. When disabled, only the Call tab will be displayed without displaying the nameBoolean typeYes

Yes - the tab names are displayed

No - only the Call tab is displayed without displaying the name

The Archive checkboxSet the checkboxDisplays the Archive tab in the interfaceBoolean typeYes

Yes - the Archive tab is displayed

No - the Archive tab is hidden

The Call control buttons checkboxSet the checkboxDisplays the buttons at the bottom of the call control panelBoolean typeYes

Yes - call control buttons are displayed

No - call control buttons are hidden

The Operator settings tab.

The table describes the parameters of the Operator settings tab.

ParameterMethod for specifying the parameterParameter descriptionPresented asDefault valueRange of values

1

The Operators tableSelect in the columnSets the list of SIP-operators who can work with this SIP-panel---
The Number columnSelect in the listSelects a SIP-operator identifierIdentifiers of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
The Subscriber columnSelect in the listSelects a SIP-operator numberNumbers of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
The Name columnSelect in the listSelects a SIP-operator name in Axxon PSIMNames of SIP-operator objects registered in the system-Depends on the number of SIP-operator objects in the system
2The All buttonClick the buttonAdds all existing SIP-operators to the table---
3The Range buttonClick the buttonOpens the Add operators window to add multiple SIP-operators---
4The Default drop-down listSelect in the listSets the default SIP-operator-Select on start
  • Select on start - when you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time you will be logged in under the previously selected SIP-operator

  • User rights - you will log into the SIP-panel as the SIP-operator that is linked to the Axxon PSIM user rights. You should also be logged into Axxon PSIM with the corresponding user rights

  • SIP-operator from the list - logging into the SIP-panel will be made at once as the selected SIP-operator. Depends on the number of SIP-operator objects in the system