Go to documentation repository
When Axxon PSIM™ software is When Axxon PSIM is installed, it is configured to operate with the Axxon PSIM MS SQL server database.
Info | ||
---|---|---|
| ||
If the current database is stored in MS Access format, it needs to be converted to MS SQL format before Axxon PSIM™ software connection PSIM connection setup. |
Info | ||
---|---|---|
| ||
If Turkish Windows OS language pack and English localization of Axxon PSIM™ PSIM are in useused, then the connected database is to must have the Latin1_General_100_CI_AS value of the Collation parameter. In most cases, the default value of the parameter should be must be used. Ensure that you have the correct language settings in the operating system. |
To connect the Axxon PSIM™ software PSIM Configuration database, do the following:
In the 1.Select or enter a server name line, select in from the list or type-in enter the name of MS SQL server which that is used to store the database to be connectedto which you want to connect.
Info | ||
---|---|---|
| ||
In case of you use dynamic host configuration protocol (DHCP) use for the local database, set «127127.0.0.1» 1 IP address (without using computer names and "local" value) in the 1.Select or enter a server name. Set «127Set 127.0.0.1» 1 value when the static IP address is useused. Otherwise, there is disconnection of Axxon PSIM™ software Axxon PSIM is disconnected with its local database when network cable is disconnected. If Axxon PSIM™ PSIM is connected to remote database configuration at by IP address (e.g.for example, 192.168.0.68\SQLEXPRESS), you cannot change and save Axxon PSIM™ software PSIM settings when there is a network connection break. If event protocol is extracted into an individual database, use any functioning way to specify a server name. |
If MS SQL server authentication is performed through the user Windows OS account, switch to the Use Windows NT Integrated security position.
Info | ||
---|---|---|
| ||
If converting conversion is performed via the remote SQL server, the computer with MS SQL server installed must show the current user account. And the user is logged on under this account at the computer that performs the database connection. |
Go to the All tab.
In the Persist Security Info field, set the True value. This is necessary to correctly save the user password.
Info | ||
---|---|---|
| ||
Each time you change the server connection parameters, you must set the Persist Security Info field value to True. |
Info | ||
---|---|---|
| ||
You must select a database at this step. If you leave the database field blank, after you close the Data Link Properties window, the line "Database is not set in connection settings" appears in the database description window of the IDB.exe utility and the OK button to save changes is inactive. |
It is strongly recommended to update We strongly recommend updating the database structure after this. For this, click the Update database button in the idb.exe utility dialog boxwindow. If DB is not updated on at this step, the update is automatically performed at at Axxon PSIM start-up; , however, it might be difficult to track errors in this case.
Note | ||
---|---|---|
| ||
If the Event Viewer is in the individual database (see Extracting event protocol into an individual database), then the Event Viewer database structure will be updated when updating the main database structure. So it is recommended to check we recommend checking the connection to the Event Viewer database before updating the main database structure in order to prevent any errors. |
Axxon PSIM™ software PSIM database is now connected.