The settings panel of the System restart service object is shown in figure.

Table describes the parameters of the object settings System restarting service.

 

Name of parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Field Identification number

Automatically

Displays the object’s identification number System restart service in the  system

 

Sequence of numbers

-

From 1 and above.

Depends on the number of objects

System restart service in the  system

 

 

2

Field

Name

Enter the value in the field

Defines the name of the object System restart service in the  system

 

 

Latin, Cyrillic and service characters

System restarting service

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols),  case-insensitive

Number of symbols – from 1 to 60.

 

3

Checkbox Disable

Is identified by the check mark

Defines the condition (enabled or disabled)  of the System restart service in the  system

 

Boolean type

No

Yes – the System restart service is disabled and is not in use

No – the System restart service is enabled and is in use.

 

4

Dropdown list Computer

Is selected from the list

Defines the parent Computer object in the system  , to which the given object System restart service refers

 

Name of the Computer objects registered in the system

 Name of the parent Computer object.

Name of the parent Computer object( object System restarting service must not be edited remotely)

 

5

Checkbox AxxonSoft USB Watch Dog for Slave.exe

Is identified by the check mark

Activates computer system of automatic restarting with the albescence of slave.exe. process’s activity

Boolean type

No

Yes – system of automatic restarting is activated

No – system of automatic restarting is deactivated

 

Control table of Intellect modules operation

6

Column Module

Automatically

Displays the list of started modules at the computer

Name f started modules

-

Depends on the number of modules, registered in the system

7

Column Status

Automatically

Displays current state of modules

Name of current states and modules

-

Loaded–module operates

Unloaded (red field) – on the expiry of waiting time interval module’s response  is abscent

Unloaded – module is unloaded.

Note. In the square brackets the time of module working since the last restartin the HH:MM:SS format  is displayed

8

Column Response time, sec

Entering of text in the field

Set waiting time interval of module’s response in seconds. With the absence of response on the expiry of set time interval the system may be restarted.

Nonnegative integers

60

From 0 and above

9

Column Quantity of restarts

Entering of text in the field

Set the maximal quantity of restarts for a period of time, specified in the column In time and Period type

Nonnegative integers

3

From 0 and above

10

Column In time

Entering of text in the field

Set period of time for which maximal quantity restarts of the system may be performed

Nonnegative integers

1

From 0 and above

11

Column Period type

Selection of value from the list

Unit s of time measurement

hours

hours –time period is measured in hours

days – time period is measured in days

12

Column Restart

Selection of value from the list

Set the type of system’s restarting

Name of possible types of restarts

Nothing

Nothing – restarting is not being performed

Module – module’s restarting is being performed

Core set – restarting of the Intellect core set is being performed

13

Column Remains of restarts

Automatically

Displays remains or restarts for a time period, set in the columns In time and Type of period

Nonnegative integers

-

Depends on the maximal quantity of restarts and on the fact how many restarts have been performed for a current time period

14

Memory (Mb) column

Setting the value in the field

Specifies the threshold of memory consumed by module. When this threshold exceeded the restart is required

Integer non-negative numbers

0

From 0 and above