Go to documentation repository
The Backup archive panel object is designed to register and configure the Backup archive panel interface object in the Axxon PSIM system, which allows the Operator configuring video data archiving.
The settings panel of the Backup archive panel object is shown in the figure.
The table describes the parameters of the settings corresponding to the elements of the settings panel of the Backup archive panel object.
№ | Parameter | Method for entering the parameter | Parameter description | Symbols used | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Backup archive panel. | Sequence of numbers | - | From 1 and above. Depends on the number of Backup archive panel objects in the digital distributed video surveillance system |
2 | Name* | Enter the value in the box | Defines the name of the Backup archive panel object. | Latin, Cyrillic and service characters | Backup archive panel | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive Number of symbols – from 1 to 60. |
3 | Disable | Is identified by the check mark | Defines the status of the Backup archive panel object. | Boolean type | Not available | Yes – the Backup archive panel is disabled and is not in use No – the Backup archive panel is enabled and is in use. |
4 | Display | Is selected from the list | Defines the parent Display object of the digital distributed system, to which the given Backup archive panel object refers. | Names of the Display objects registered in the system. | Name of the parent Display. | Depends on the number of Display objects in the digital distributed video surveillance system |
5 | Backup archive* | Is selected from the list | Defines an Backup archive, which the Operator will control with the Backup archive panel interface object. | Name of the Backup archive objects registered in the system. | - | Depends on the number of Backup archive objects in the digital distributed video surveillance system. |
6 | Fixed position | Is set with a check mark | Defines, if the user can drag the Backup archive panel over the screen with the mouse. | Boolean type | Not available | Yes – the Backup archive panel may not be dragged. No – the Backup archive panel may be dragged. |
7 | X | Enter the value in the box (Automatically, if the Fixed position option is checked). | Defines a coordinate in the X horizontal axis for the upper left corner of the Backup archive panel on the screen. | % of the screen width. | Not defined | From 0 to M*100, where M is the number of video monitors installed. |
8 | Y | Enter the value in the box (Automatically, if the Fixed position option is checked). | Defines a coordinate in the Y vertical axis for the upper left corner of the Backup archive panel on the screen. | % of the screen height. | Not defined | From 0 to M*100, where M is the number of video monitors installed. |
9 | W | Enter the value in the box (Automatically, if the Fixed position option is checked). | Defines the width of the Backup archive panel. | % of the screen width. | Not defined | From 0 to M*100, where M is the number of video monitors installed. |
10 | H | Enter the value in the box (Automatically, if the Fixed position option is checked). | Defines the height of the Backup archive panel. | % of the screen width. | Not defined | From 0 to M*100, where M is the number of video monitors installed. |