The Alarm Message Window object is designed to display an interface box showing the alarm event, which is initiated by the Axxon PSIM digital video surveillance system.

The settings panel of the Alarm Message Window object is shown in figure.

Table describes the parameters of the settings corresponding to the elements of the settings panel of the Alarm Message Window object.

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Alarm Message Window object in the digital  distributed video surveillance system.

Sequence of numbers

-

From 1 and above.

Depends on the number of Alarm Message Window objects in the digital distributed video surveillance system.

2

Name*

Enter the value in the field

Defines the name of the Alarm Message Window object in the digital distributed video surveillance system.

Latin, Cyrillic and service characters

Alarm notification window

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Is identified by the check mark

Defines the condition of the Alarm Message Window object (enabled or disabled) in the digital distributed video surveillance system.

Boolean type

Not availab-le

Yes – the Alarm Message Window object is disabled and is not in use.

No – the Alarm Message Window object is enabled and is in use.

4

Computer

Is selected from the list

Defines the parent Computer object of the digital distributed video surveillance system, to which the given Alarm Message Window object refers.

Name of the Computer objects registered in the system

Name of the parent Computer object.

Depends on the number of Computer objects in the digital distributed video surveillance system

5

X

Enter the value in the field.

Defines the coordinate in the X horizontal axis for the upper left corner of the Alarm Message Window on the screen.

% of the screen width.

Not defined

From 0 to M*100, where M is the number of surveillance monitors installed.

6

Y

Enter the value in the field.

Defines the coordinate in the Y vertical axis for the upper left corner of the Alarm Message Window on the screen.

% of the screen height.

Not defined

From 0 to M*100, where M is the number of surveillance monitors installed.

*The name of the element is not displayed in the settings panel of the given object.