The Telemetry controller object is designed to register and configure serial ports (COM) used for connecting the PTZ units of the Axxon PSIM™ system.
The settings panel of the Telemetry controller object is shown in figure.
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Telemetry controller object.
№
| Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Telemetry controller object in the digital distributed video surveillance system. | Sequence of numbers | - | Depends on the number of Telemetry controller objects in the digital distributed video surveillance system |
2 | Name* | Enter the value in the field | Defines the name of the Telemetry controller object in the digital distributed video surveillance system. | Latin, Cyrillic letters and service characters | Telemetry controller No. | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. Number of symbols – from 1 to 60. |
3 | Disable | Is identified by the check mark | Defines the condition of the Telemetry controller object (enabled or disabled) in the digital distributed video surveillance system. | Boolean type | Not available | Yes – the Telemetry controller object is disabled and is not in use No – the Telemetry controller is enabled and is in use. |
4 | Computer | Is selected from the list | Defines the parent Computer object of the digital distributed video surveillance system, to which the given Telemetry controller object refers. | Name of the Computer objects registered in the system | Name of the parent Computer object. | Depends on the number of Computer objects in the digital distributed video surveillance system |
Settings Group | ||||||
5 | Controller type* | Is selected from the list | Defines the data communication protocol with the PTZ unit over the serial port (COM). Data communication protocols are supplied by the PTZ vendors. | Name of the PTZ units integrated in the system. | Videotec | Corresponds to the list of the PTZ units integrated in the system. |
6 | Port | Is selected from the list | Defines the number of the COM port of the computer, to which PTZ will be connected. | List of COM ports available | COM1 | Depends on the number of COM ports in the videoserver or Remote administrator workstation. If a non-empty value is selected, then the local COM port priority while handling PTZ device commands is higher than other devices. Otherwise, the COM port priority is set to the default value. |
7 | Speed | Is selected from the list | Defines the data communication rate for the COM port. | Kb/sec
| 9600 | From 300 to 256000. |
8 | Parity | Is selected from the list | Defines the parity check mode for the data transmission over the COM port. | List of parity check modes. | None | Even, Odd, None, Mark, Space. |
9 | DTR | Is identified by the check mark. | Defines the power supply to the PTZ unit via the DTP COM port. | Boolean type | Yes | Yes – the power will be supplied via the DTR port. No – the power will not be supplied via the DTR port. |
10 | RTS | Is identified by the check mark. | Defines the power supply to the PTZ unit via the RTS COM port. | Boolean type | Yes | Yes – the power will be supplied via the RTS port. No – the power will not be supplied via the RTS port. |
*Name of the element is not displayed in the settings panel of the given object.