The settings panel of the System restart service object is shown in the figure.
Table describes the setting parameters of the System restart service object.
№
| Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Identification number | Automatically | Displays the identification number of the System restart service object in the system | Sequence of numbers | - | From 1 and above. Depends on the number of the System restart service objects in the system |
2 | Name | Enter the value into the field | Sets the name of the System restart service object in the system | Latin, Cyrillic and service characters | System restart service | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of symbols – from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (enabled or disabled) of the System restart service object in the system | Boolean type | Clear | Set – the System restart service object is disabled and isn't used Clear – the System restart service object is enabled and used |
4 | Computer | Select the value from the list | Sets the Computer parent object in the system, to which the given System restart service object belongs | Name of the Computer objects registered in the system | Name of the Computer parent object | Name of the Computer parent object (the System restart service object cannot be edited remotely) |
5 | AxxonSoft USB Watchdog for PSIM_Host.exe | Set the checkbox | Activates the system of the computer automatic restart when the PSIM_Host.exe process isn't active | Boolean type | Clear | Set – the system of automatic restart is activated Clear – the system of automatic restart is deactivated |
Table of the performance monitoring of Axxon PSIM modules | ||||||
6 | Module | Automatically | Displays the list of the modules running on the computer | Names of the running modules | - | Depends on the number of the modules registered in the system |
7 | Status | Automatically | Displays the current state of the modules | Names of the current states of the modules | - | loaded – module runs unloaded (red field) – no response from the module after the waiting time expires unloaded – module is unloaded Note. The time of the module run time since the last restart is displayed in the HH:MM:SS format in the square brackets |
8 | Response time, s | Enter the value into the field | Sets the time interval in seconds of the module response time. If there is no response after the specified time, the system can be restarted | Non-negative integers | 60 | From 0 and above |
9 | Quantity of restarts | Enter the value into the field | Sets the maximal quantity of restarts for a period of time, specified in the In time and Type of period columns | Non-negative integers | 3 | From 0 and above |
10 | In time | Enter the value into the field | Set period of time during which the maximum quantity of the system restarts can be performed | Non-negative integers | 1 | From 0 and above |
11 | Type of period | Select the value from the list | Names of time period units | hours | hours – the time period is measured in hours days – the time period is measured in days | |
12 | Restart | Select the value from the list | Sets the type of the system restart | Names of the possible types of restart | none | none – restart isn't performed module – module restart is performed core set – Axxon PSIM core restart is performed |
13 | Remains of restarts | Automatically | Displays the quantity of the remaining restarts for the period specified in the In time and Type of period columns | Non-negative integers | - | Depends on the maximum quantity of restarts and on the number of restarts that were performed for a current time period |
14 | Memory (Mb) | Enter the value into the field | Sets the module memory consumption threshold above which the module should be restarted | Non-negative integers | 0 | From 0 and above |