Go to documentation repository
The settings panel of the Video capture device object is shown in the figure.
Table describes the setting parameters of the Video capture device object.
№ | Parameter | Method for setting the parameter value | Parameter description | Presented as | Default value | Value range |
1 | Identification number | Automatically | Displays the identification number of the Video capture device system object | Sequence of numbers | - | Depends on the number of the Video capture device objects in the system |
2 | Name | Enter the value in the field | Sets the name of the Video capture device object in the system | Latin, Cyrillic letters and service characters | Video capture device | A line representing a sequence of any symbols (letters, digits, service characters except > and < symbols), case-insensitive. Number of symbols — from 1 to 60 |
3 | Disable | Set the checkbox | Sets the status (enabled or disabled) of the Video capture device object in the system | Boolean type | - | Set — the Video capture device object is disabled and isn't in use Clear — the Video capture device object is enabled and is in use |
4 | Computer | Select from the list | Sets the Computer parent object for this Video capture device object | Name of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the system |
The Basic settings group | ||||||
5 | Type | Select from the list | Sets the type of the video capture board or the manufacturer of the IP device | Name of the types of the video capture boards and the manufacturers of the IP devices | - | Video capture boards (FS-3, FS-5, FS-6, FS-8, WS–4, WS-7/17, etc.). Network video hubs (WaveHub) Network devices (Axis, Panasonic, etc.) Virtual |
6 | Model | Select from the list | Sets the model of the IP device | Names of the models of the IP devices | Integrated models of the IP devices of the selected manufacturer | |
7 | Firmware | Select from the list | Sets the firmware of the IP device | Numbers of the integrated firmware of the IP device | Integrated firmware of the selected IP device | |
8 | PCI channel | Select from the list | Sets number of the PCI channel of the video capture board ADC | List of connected channels for video capture | - | From 0 to 31, depending on the number of the PCI channels on the Server and the number of installed ADCs |
9 | Signal | Select from the list | Sets the format of the incoming video signal | List of video signal formats | PAL | PAL, NTSC |
10 | Resolution | Select from the list | Sets resolution of the video frames | List of video frame resolutions | Standard | Standard High Full Specific values depend on the camera model |
11 | Speed | Set in the required position | Sets the frame rate of the video stream | Permissable changes of the total frame rate of the video signal transmission | Average | Depends on the capabilities of the IP-camera or video capture board. For boards with software compression: Max — maximum permissable total frame rate of the video signals Average — half of the maximum permissable total frame rate of the video signals Min — one third of the maximum permissable total frame rate of the video signals |
12 | IP address | Enter the value in the field | Sets the IP address of the network device | IP address | - | A line presented as xxx.xxx.xxx.xxx Contains the values: 0.0.0.0 – 255.255.255.255 Depends on the network settings of the IP devices registered in the system When configuring getting live video from the ECHD Server, specify the following line in the field <ECHD Server address>:<GUID cameras in the system>:<external account> |
13 | Port | Enter the value in the field | Sets the connection port of the network IP device | Nonnegative integer | - | From 0 to 65535 Depends on the network settings of the IP device |
14 | RTSP | Enter the value in the field | Sets the RTSP connection port of the network IP device | Nonnegative integer | - | From 0 to 65535 Depends on the network settings of the IP device |
15 | Name | Enter the value in the field | Set the user name to connect to the network IP device | - | - | Depends on the network settings of the IP device |
16 | Password | Enter the value in the field | Sets the password to connect to the network IP device | - | - | Depends on the network settings of the IP device |
17 | Activate watchdog | Set the checkbox | Activates the Windows reset function, when Axxon PSIM main modules freeze | Boolean type | Clear | Set — the reset funcion of Windows OS is enabled Clear — the reset funcion of Windows OS is disabled |
18 | Use device settings | Set the checkbox | Allows using the settings specified in the Web-Server or other software of the IP device | Boolean type | Clear Note. When creating the Video capture device object using the Camera discovery tool, the value of the checkbox depends on the settings configured in the Wizard | Set — the settings of the IP device are used Clear — the settings of Axxon PSIM are used |