The Script object is designed to create specialized programs in JScript language. The settings panel of the Script is shown in the figure.

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Script object.

Table 11.2—47

Parameter

Method for entering the parameter

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Shows the identification number of the Script object in the digital video surveillance system.

Sequence of numbers

-

Depends on the number of Script objects in the digital distributed video surveillance system

2

Name*

Specify the value in the field

Assigns the name to the Script object.

Latin, Cyrillic and service characters

Script

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), case-insensitive

Number of symbols – from 1 to 60.

3

Disable

Checkbox is set

Sets the state (enabled or disabled) of the Script object in the digital distributed video surveillance system.

Boolean type

Not available

Yes – the Script object is disabled and is not in use

No – the Script object is enabled and is in use.

4

Time zone

Select in the list

Specifies the time period for the operation of the given program.

Time zone name registered in the system.

Never

Never – the program will never be executed.

Always – the program is always executed.

List of created time zones – the programs are executed during the time period as defined by the time zone.

The Computers group

5

Select element*

Checkbox is set

Assigns the computer for the execution of the given script.

Boolean type

No

Yes – the script is executed on the computer.

No – the script is not executed on the computer.

6

Computer

Automatically

Specifies the computer name in the local network

Computer name in the local network.

Computer name in the local network.

A line containing a sequence of any symbols (letters, digits, service characters), case-insensitive

Number of symbols - 60.

7

Name

Automatically

Specifies the name of the computer in the digital distributed video surveillance system.

Name of the Computer object registered in the system.

Name of the Computer object registered in the system.

A line containing a sequence of any symbols (letters, digits, service characters), case-insensitive

Number of symbols - 60.

No group

8

Text editor*

Specify the value in the field

Specifies the text of the executed script.

Latin, Cyrillic and service characters

Not set

A line containing a sequence of any symbols (letters, digits, service characters), case-insensitive

Unlimited number of symbols.

9

Editor - Debugger

Press the button

Gives a command to open a debugging window of the script.

-

-

-

10

Object’s type

Select in the list

Sets the type of the object on receiving event from which the script is executed

Types of objects registered in the system

-

Depends on the number of the objects registered in the system

11

Identifier

Select in the list

Sets the identifier of the object on receiving event from which the script is executed

Identifiers of the objects of the selected type registered in the system

-

Depends on the number of the objects of the selected type registered in the system

12

Object’s name

Automatically  

Sets the name of the object on receiving event from which the script is executed

The name of the object of the selected type with the selected identifier

-

Depends on user’s entering 

13

Event

Specify the value in the field

Sets the event on receiving which the script is executed

Events supported by the object

-

Depends on events supported by the object.  The name of the event is to be specified in upper case.

*The name of the element is not displayed in the settings panel of this object.