Go to documentation repository
Previous page Next page
The Load configuration function allows loading the configuration parameters from a file with the .cfg extension created using the Save configuration function (see Save configuration function). You can apply the configuration parameters only to the object of the same type that is used to create the configuration file.
After you select the Load configuration menu item, a standard Windows dialog window appears, in which you must specify the required configuration file.
Note
Some configuration parameters that must be unique for the objects of the given type may not be applied after the configuration is loaded.
For example, the PCI channel parameter of the Video capture device object isn't changed according to the configuration file if the Video capture device object of the same type already exists in the objects tree and has the same PCI channel parameter value. For more information on allocation of the PCI channels between the Video capture device objects, see Creating and configuring the Video capture device object in the Guide for installing and configuring security system components.