New Features and Improvements

  1. Introduced a full-fledged system configuration in a distributed configuration. Now you can create and configure Monitoring objects on other computers from one computer 
  2. It is now possible to attach video data from different cameras to an alarm message 
  3. Increased the number of alarm groups for displaying the alarm messages: 
    • In the Agent of Control settings, two new groups are added to the existing alarm groups "Hardware", "ACS", "FSA" and "Detection tools/Detectors" - "Extra 1" and "Extra 2".
    • In the Monitoring interface object settings, also two new alarm groups are added - "Extra 1" and "Extra 2". Alarm group "Extra 1" replaced the previously existing "Temperature sensors" group. The names of these alarm groups can be edited.
  4. Improved the Monitoring interface object. Objects on the Control panel and Owner panel can now be scaled 
  5. Improved the Monitoring Reports interface object. Added new group of reports "Operator actions". This group includes the following reports: 
    • Accepted alarms
    • Build reports
    • Search in archive
    • Other operator actions
  6. The "System failures" and "Alarms" reports can now be generated using a script 
  7. Improved the algorithm for generating the "Archive size too small" alarm 
  8. In the distributed configuration, it is now possible to make audio calls between the Server of Control operators and the Agent of Control operators from the Monitoring interface object. The calls are made using the SIP terminal object without using physical SIP devices 
  9. Now Agent of Control is automatically added to the Server of Control settings at the first connection 
  10. The Server of Control now receives the information about the total RAM size on Agent of Control. You can view this information in the "Show detailed information" window 
  11. Improved the Monitoring interface object. The statistics for cameras (total / OK / faulty) are displayed both for the entire system and for each Agent of Control separately 
  12. Increased the length of the text description of the monitoring event to 60 characters 
  13. Increased the number of Partitions of Control subordinate to Agent of Control to 255 

Bug Fixes

  1. Fixed a bug that prevented Agent of Control from receiving alarm events if Partition of Control number contained letters
  2. Fixed an issue of Agent of Control not recognizing the Guardant hardware dongle
  3. Fixed an issue with displaying duplicate entries in crash reports
  4. A number of minor bugs fixed
  5. Some fixes and improvements in the documentation
  • No labels