The Load configuration function allows loading configuration parameters from a file with the .cfg extension that has been created using the Save configuration function (see the section Save configuration function). Configuration parameters can be applied only for objects of the type used to create the configuration file.

 

After Load configuration is selected in the menu, a standard Windows dialog box appears, in which you can navigate to the necessary configuration file.

Note.

Some configuration parameters that must be unique for objects of the given type are not applied when a configuration is loaded.

For example, the PCI channel parameter for the Video Capture Device object is not changed to the value given in a configuration file if an existing Video Capture Device object in the device tree already has the same PCI channel value. For more information on allocation of PCI channels between Video Capture Device objects, go to the section Creating and configuring the Video Capture Device object in the Installing and configuring security system components guide.