Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Release Notes  Axxon PSIM 1.0.0 Release Notes Next page


Incident manager

  1. Improved the window for adding multiple events to the Incident handler (the Add button on the Incident handler settings panel):

    1. all columns are now sorted alphabetically by default;

    2. added Autoescalation;

    3. added the ID column to the object names table;

    4. improved the design for logic, priority and timer setting

  2. In the Incident manager, it is now possible to set the minimum and maximum height for a comment in the event handling logic

  3. Added the UPDATE_ESCALATE_STATUS command to Incident manager. The command can be used in scripts for escalating the specified events

  4. It is now possible to use an external database for the Incident Server

  5. In the Incident manager, updated the Last comment and All comments columns: now only the first line of the comment is displayed in them, and the full comment is displayed in the tooltip

  6. Updated the Incident handler: now when you select the events for display and processing, you can select any camera events, not just alarms

  7. Added the event Resolution (Canceled or Processed) to the Operator actions report.

Video surveillance monitor

  1. Added the Button functionality to the Video surveillance monitor. The Button is displayed in the Surveillance window of a camera and performs the specified actions when clicked
  2. Now, in the Video surveillance monitor, the Direct3D display mode is used by default instead of DirectDraw

  3. In the Monitor object, added a column with a unique camera identifier (Guid) to the table of the List of cameras tab

  4. Now, the sorting of the cameras list in the Video surveillance monitor function menu (by ID or by name) can be set using the SortCamsById registry key

  5. Now, when activating the archive video from the Map, the corresponding camera name is displayed in the Surveillance window.
  6. Added the Computer column to the window for selecting video cameras in bulk in the Video surveillance monitor. Using this column, you can sort the cameras available for adding
  7. Adjusted the name settings for the final export file in the Export period:

    1. if the Default file name checkbox is set, then the resulting file will have the name "<Camera and camera number><Date and time><Video episode number>.avi".

    2. if the Default file name checkbox is clear, then the file path becomes editable and you can set your own file name in it.

Event Viewer

  1. Added the SET_FILTERS command to the Event Viewer (EVENT_VIEWER), which can be used in scripts to filter out the events.

  2. Now you can minimize the Event Viewer interface window on the screen. To do this, set the value 1 to the new ShowInTaskbar registry key
  3. Optimized the process of cleaning the database from events older than the specified storage period: now the cleaning starts every three minutes and deletes 100,000 events, starting with the oldest

Videogate

  1. Added a new GateDisableHotStartVideo key that disables the start of retransmission and video recording
  2. Added the START_VIDEO and STOP_VIDEO commands to start and stop the camera video stream and writing to the archive
  3. Updated settings for recording to the Videogate archive

Map

  1. Added events to the Map (MAP):

    1. ACTIVATE_OBJECT—activation of the object. The event is received when an object is selected (activated by a single mouse click) on the Map and contains the layer parameter—the identifier of the layer on which the event occurred;

    2. OBJDBLCLK—the event is received when you double-click an object on the Map

  2. Implemented display of the moving objects tracks on the Map (displayed using arrows). For this, the DRAW_ARROW command is used, which is implemented in the Face PSIM 1.0.1 vertical solution

SIP-terminal

  1. The configuration of a SIP-terminal can now be transferred to a backup server in case of the connection with the main server is lost (Failover service). To do this, specify the IP address of the backup server in the sip_terminal.config file. By default, the file is located in the <Axxon PSIM installation directory>\Modules folder
  2. Added the support for the PCMA codec.

Registry keys

  1. Optimized system performance when the MemFile registry key value is set to -1 (default):

    1. now the statistics displays the buffer size for writing, the limit of which is set in the WriteBufferSize parameter;

    2. added the FileSystem.PreAllocateFileSize parameter, which sets the minimum size of the created temporary file. The parameter determines the size of the temporary files that will be created by default;

    3. added the FileSystem.WriteBufferMemoryLimit parameter, which sets the maximum possible size of the RAM buffer for the channel before the data from the buffer is written to the archive.
      These improvements are made so that frames are not skipped when recording to archive under high system load

  2. Added the StatusInfo registry key, which enables the recording of detailed statistics (including statistics per camera) about the system every 10 seconds in the video.run log files
  3. Added the CanUseVfwApi registry key for AviExport, which changes the codec used when exporting to avi format (Vfw or FFmpeg)

Other improvements

  1. Added a new SCRIPT_ERROR event for the SLAVE object. This event is generated if the script execution fails

  2. For the API request for receiving video subsystem events http://IP-address:port/web2/secure/events/ added the ability to specify several objects separated by commas in the objectId parameter, and to receive all triggers from objects of the same type

  3. Added the support of the TLS version 1.2 certificate to the Web-Server.

  4. In the dbo.OBJ_PERSON table of the main Axxon PSIM database, increased the character limit for visit_document from 120 to 255
  5. Introduced the new ArchProbe utility, which can help you check the integrity of video archive files recorded in the Axxon PSIM internal format. The utility is located in the <Axxon PSIM installation directory>\Tools folder and is launched in the Command line. In the utility, specify the path to the folder with archive records or to a specific recording. As a result, information on each recording of the specified video archive will be displayed.
  6. Now Axxon Player generates an AxxonPlayer.lh text file, which contains the log of video archive views via the Player

  7. In User permissions, added the Allow VMDA filters use option which allows the Operator to use templates

  8. Improved the operation of the RTSP Server: now when you change the playback speed of the archive, or when you change the stream, the transmission isn’t interrupted
  9. Added new fields to the UPDATE_PROTOCOL table with the information about the type of changes made to user permissions
  10. Improved Manitou integration: now you can set the tag values to be sent
  11. Now in the Active Directory synchronization window, the first and last name of the added users is displayed, and you can select users using checkboxes.

IP device support

The release includes the Drivers Pack 3.75.30 for IP devices support. Detailed information about the Drivers Pack, where to find the latest set of drivers, and the list of supported hardware is available at https://www.axxonsoft.com/integrated_security_solutions/supported-ip/.

Updating from previous version

Run the newer version installation program and install Axxon PSIM over the 1.0.0 version. No need for uninstalling.

Product documentation

System Requirements

Installing the Axxon PSIM Software

License key

Complete Axxon PSIM Documentation